CVE-2022-31810
Full vulnerability record from the local CVENow database.
Description
A vulnerability has been identified in SiPass integrated (All versions < V2.90.3.8). Affected server applications improperly check the size of data packets received for the configuration client login, causing a stack-based buffer overflow. This could allow an unauthenticated remote attacker to crash the server application, creating a denial of service condition.
Severity
HIGH
CVSS score
7.5
(v3.1)
Vulnerability status
Modified
Source identifier
Published
2023-07-11 10:15:10.127000
Last modified
2026-10-23 23:10:00.157000
View original CVE JSON
{
"id": "CVE-2022-31810",
"sourceIdentifier": "[email protected]",
"published": "2023-07-11T10:15:10.127",
"lastModified": "2026-10-23T23:10:00.157",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SiPass integrated (All versions < V2.90.3.8). Affected server applications improperly check the size of data packets received for the configuration client login, causing a stack-based buffer overflow.\r\n\r\nThis could allow an unauthenticated remote attacker to crash the server application, creating a denial of service condition."
},
{
"lang": "es",
"value": "Una vulnerabilidad ha sido identificada en SiPass integrated (Todas las versiones anteriores a V2.90.3.8). Las aplicaciones de servidor afectadas comprueban incorrectamente el tamaño de los paquetes de datos recibidos para el inicio de sesión del cliente de configuración, causando un desbordamiento de búfer basado en pila.\n\nEsto podría permitir a un atacante remoto no autenticado bloquear la aplicación de servidor, creando una condición de denegación de servicio."
}
],
"affected": [
{
"source": "[email protected]",
"affectedData": [
{
"vendor": "Siemens",
"product": "SiPass integrated",
"defaultStatus": "unknown",
"versions": [
{
"version": "All versions < V2.90.3.8",
"status": "affected"
}
]
}
]
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "[email protected]",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
},
{
"source": "[email protected]",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"timestamp": "2025-03-05T18:38:55.893124Z",
"id": "CVE-2022-31810",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
]
},
"weaknesses": [
{
"source": "[email protected]",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-20"
}
]
},
{
"source": "[email protected]",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:sipass_integrated:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.90.3.8",
"matchCriteriaId": "AC7AA710-4928-4B8B-AF56-24E4F5548AEA"
}
]
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-924149.pdf",
"source": "[email protected]",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-924149.pdf",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
]
}
]
}