CVE-2023-24549
Full vulnerability record from the local CVENow database.
Description
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.
Severity
HIGH
CVSS score
7.8
(v3.1)
Vulnerability status
Modified
Source identifier
Published
2023-02-14 11:15:14.880000
Last modified
2026-10-23 23:10:00.157000
View original CVE JSON
{
"id": "CVE-2023-24549",
"sourceIdentifier": "[email protected]",
"published": "2023-02-14T11:15:14.880",
"lastModified": "2026-10-23T23:10:00.157",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process."
},
{
"lang": "es",
"value": "Una vulnerabilidad ha sido identificada en Solid Edge SE2022 (Todas las versiones anteriores a V222.0MP12), Solid Edge SE2023 (Todas las versiones anteriores a V223.0Update2). La aplicación afectada es vulnerable a desbordamiento de búfer basado en pila al analizar archivos PAR especialmente diseñados. Un atacante podría aprovechar esta vulnerabilidad para ejecutar código en el contexto del proceso actual."
}
],
"affected": [
{
"source": "[email protected]",
"affectedData": [
{
"vendor": "Siemens",
"product": "Solid Edge SE2022",
"defaultStatus": "unknown",
"versions": [
{
"version": "All versions < V222.0MP12",
"status": "affected"
}
]
},
{
"vendor": "Siemens",
"product": "Solid Edge SE2023",
"defaultStatus": "unknown",
"versions": [
{
"version": "All versions < V223.0Update2",
"status": "affected"
}
]
}
]
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "[email protected]",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
},
{
"source": "[email protected]",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"timestamp": "2025-03-20T16:09:17.258625Z",
"id": "CVE-2023-24549",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
]
},
"weaknesses": [
{
"source": "[email protected]",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-121"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2210.0002.004",
"matchCriteriaId": "0C855788-002F-41E5-BC01-8597E66EDE1C"
}
]
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf",
"source": "[email protected]",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [