CVE-2023-24566
Full vulnerability record from the local CVENow database.
Description
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19472)
Severity
LOW
CVSS score
3.3
(v3.1)
Vulnerability status
Modified
Source identifier
Published
2023-02-14 11:15:16.307000
Last modified
2026-10-24 13:10:00.147000
View original CVE JSON
{
"id": "CVE-2023-24566",
"sourceIdentifier": "[email protected]",
"published": "2023-02-14T11:15:16.307",
"lastModified": "2026-10-24T13:10:00.147",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19472)"
},
{
"lang": "es",
"value": "Una vulnerabilidad ha sido identificada en Solid Edge SE2022 (todas las versiones anteriores a V222.0MP12), Solid Edge SE2022 (todas las versiones), Solid Edge SE2023 (todas las versiones anteriores a V223.0Update2). La aplicación afectada es vulnerable a un desbordamiento de búfer basado en pila al analizar archivos PAR especialmente diseñados. Un atacante podría aprovechar esta vulnerabilidad para ejecutar código en el contexto del proceso actual. (ZDI-CAN-19472)"
}
],
"affected": [
{
"source": "[email protected]",
"affectedData": [
{
"vendor": "Siemens",
"product": "Solid Edge SE2022",
"defaultStatus": "unknown",
"versions": [
{
"version": "All versions < V222.0MP12",
"status": "affected"
}
]
},
{
"vendor": "Siemens",
"product": "Solid Edge SE2022",
"defaultStatus": "unknown",
"versions": [
{
"version": "All versions",
"status": "affected"
}
]
},
{
"vendor": "Siemens",
"product": "Solid Edge SE2023",
"defaultStatus": "unknown",
"versions": [
{
"version": "All versions < V223.0Update2",
"status": "affected"
}
]
}
]
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "[email protected]",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
"baseScore": 3.3,
"baseSeverity": "LOW",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 1.8,
"impactScore": 1.4
},
{
"source": "[email protected]",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"timestamp": "2025-03-20T15:06:05.105221Z",
"id": "CVE-2023-24566",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
]
},
"weaknesses": [
{
"source": "[email protected]",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-121"
}
]
},
{
"source": "[email protected]",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2210.0002.004",
"matchCriteriaId": "0C855788-002F-41E5-BC01-8597E66EDE1C"
}
]
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf",
"source": "[email protected]",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
]
}
]
}