CVE-2023-27409
Full vulnerability record from the local CVENow database.
Description
A vulnerability has been identified in SCALANCE LPE9403 (All versions < V2.1). A path traversal vulnerability was found in the `deviceinfo` binary via the `mac` parameter. This could allow an authenticated attacker with access to the SSH interface on the affected device to read the contents of any file named `address`.
Severity
LOW
CVSS score
3.3
(v3.1)
Vulnerability status
Modified
Source identifier
Published
2023-05-09 13:15:16.800000
Last modified
2026-10-24 13:10:00.147000
View original CVE JSON
{
"id": "CVE-2023-27409",
"sourceIdentifier": "[email protected]",
"published": "2023-05-09T13:15:16.800",
"lastModified": "2026-10-24T13:10:00.147",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE LPE9403 (All versions < V2.1). A path traversal vulnerability was found in the `deviceinfo` binary via the `mac` parameter. This could allow an authenticated attacker with access to the SSH interface on the affected device to read the contents of any file named `address`."
},
{
"lang": "es",
"value": "Una vulnerabilidad ha sido identificada en SCALANCE LPE9403 (Todas las versiones anteriores a V2.1). Una vulnerabilidad de salto de ruta fue encontrada en el binario 'deviceinfo' a través del parámetro 'mac'. Esto podría permitir a un atacante autenticado con acceso a la interfaz SSH en el dispositivo afectado leer el contenido de cualquier archivo llamado 'address'."
}
],
"affected": [
{
"source": "[email protected]",
"affectedData": [
{
"vendor": "Siemens",
"product": "SCALANCE LPE9403",
"defaultStatus": "unknown",
"versions": [
{
"version": "All versions < V2.1",
"status": "affected"
}
]
}
]
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "[email protected]",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N",
"baseScore": 2.5,
"baseSeverity": "LOW",
"attackVector": "LOCAL",
"attackComplexity": "HIGH",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 1.0,
"impactScore": 1.4
},
{
"source": "[email protected]",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"baseScore": 3.3,
"baseSeverity": "LOW",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 1.8,
"impactScore": 1.4
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"timestamp": "2025-01-28T16:47:07.143646Z",
"id": "CVE-2023-27409",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
]
},
"weaknesses": [
{
"source": "[email protected]",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-22"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:siemens:scalance_lpe9403_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.1",
"matchCriteriaId": "E4B6DB46-5FD2-4ABD-B1A5-7AB8BB3724BB"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:siemens:scalance_lpe9403:-:*:*:*:*:*:*:*",
"matchCriteriaId": "52A77C9D-E59C-4397-B834-797D7B334A6B"
}
]
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-325383.pdf",
"source": "[email protected]",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-325383.pdf",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
]
}
]
}