← Back to CVE Explorer

CVE-2024-45162

Full vulnerability record from the local CVENow database.

Description

A stack-based buffer overflow issue was discovered in the phddns client in Blu-Castle BCUM221E 1.0.0P220507 via the password field.

Severity
CRITICAL
CVSS score
9.8 (v3.1)
Vulnerability status
Deferred
Source identifier
Published
2025-10-29 14:15:50.607000
Last modified
2026-11-09 10:10:00.217000
View original CVE JSON
{
  "id": "CVE-2024-45162",
  "sourceIdentifier": "[email protected]",
  "published": "2025-10-29T14:15:50.607",
  "lastModified": "2026-11-09T10:10:00.217",
  "vulnStatus": "Deferred",
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A stack-based buffer overflow issue was discovered in the phddns client in Blu-Castle BCUM221E 1.0.0P220507 via the password field."
    },
    {
      "lang": "es",
      "value": "Un problema de desbordamiento de búfer basado en pila fue descubierto en el cliente phddns en Blu-Castle BCUM221E 1.0.0P220507 a través del campo de contraseña."
    }
  ],
  "affected": [
    {
      "source": "[email protected]",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "version": "n/a",
              "status": "affected"
            }
          ]
        }
      ]
    }
  ],
  "metrics": {
    "cvssMetricV31": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary",
        "cvssData": {
          "version": "3.1",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "attackVector": "NETWORK",
          "attackComplexity": "LOW",
          "privilegesRequired": "NONE",
          "userInteraction": "NONE",
          "scope": "UNCHANGED",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "availabilityImpact": "HIGH"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "timestamp": "2025-10-29T14:16:41.947204Z",
          "id": "CVE-2024-45162",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "role": "CISA Coordinator",
          "version": "2.0.3"
        }
      }
    ]
  },
  "weaknesses": [
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary",
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ]
    }
  ],
  "references": [
    {
      "url": "https://blu-castle.com/",
      "source": "[email protected]"
    },
    {
      "url": "https://www.gruppotim.it/it/footer/red-team/2024/CVE-2024-45162-Blu-Castle_BCUM221E1.html",
      "source": "[email protected]"
    }
  ]
}