Description
EMCLI contains a high severity vulnerability where improper neutralization of special elements used in an OS command could be exploited leading to Arbitrary Code Execution.
Severity
HIGH
CVSS score
8.4
(v3.1)
Vulnerability status
Deferred
Source identifier
85b1779b-6ecd-4f52-bcc5-73eac4659dcf
Published
2025-10-13 07:15:48.883000
Last modified
2026-10-18 21:10:00.120000
View original CVE JSON
{
"id": "CVE-2025-0636",
"sourceIdentifier": "85b1779b-6ecd-4f52-bcc5-73eac4659dcf",
"published": "2025-10-13T07:15:48.883",
"lastModified": "2026-10-18T21:10:00.120",
"vulnStatus": "Deferred",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "EMCLI contains a high severity vulnerability where improper neutralization of special elements used in an OS command could be exploited leading to Arbitrary Code Execution."
},
{
"lang": "es",
"value": "EMCLI contiene una vulnerabilidad de alta gravedad donde una neutralización inadecuada de elementos especiales utilizados en un comando del sistema operativo podría ser explotada, lo que llevaría a la ejecución de código arbitrario."
}
],
"affected": [
{
"source": "85b1779b-6ecd-4f52-bcc5-73eac4659dcf",
"affectedData": [
{
"vendor": "Ericsson",
"product": "Site Controller 6610",
"defaultStatus": "unaffected",
"versions": [
{
"version": "0",
"lessThan": "S24.Q2",
"versionType": "custom",
"status": "affected",
"changes": [
{
"at": "S24.Q2, S24.Q3.1 S24.Q4 S25.Q1",
"status": "unaffected"
}
]
}
]
},
{
"vendor": "Ericsson",
"product": "RAN Compute (all BB versions)",
"defaultStatus": "unaffected",
"versions": [
{
"version": "0",
"lessThan": "24.Q1.C5",
"versionType": "custom",
"status": "affected",
"changes": [
{
"at": "4.Q1.C5 24.Q2 24.Q3 24.Q4 25.Q1 RCG123.1 RCG123.2 RCG123.3",
"status": "unaffected"
}
]
}
]
}
]
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "85b1779b-6ecd-4f52-bcc5-73eac4659dcf",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "REQUIRED",
"scope": "CHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 1.7,
"impactScore": 6.0
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"timestamp": "2025-10-14T13:25:34.279595Z",
"id": "CVE-2025-0636",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
]
},
"weaknesses": [
{
"source": "85b1779b-6ecd-4f52-bcc5-73eac4659dcf",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"references": [
{
"url": "https://www.ericsson.com/en/about-us/security/psirt/cve-2025-0636",
"source": "85b1779b-6ecd-4f52-bcc5-73eac4659dcf"
}
]
}