CVE-2025-13833
Full vulnerability record from the local CVENow database.
Description
A vulnerability exists in SecureConnector for Windows when the “Additional Appliance Connections” setting is enabled and the agent’s configuration file contains more than three trusted‑server entries. Some entries omit TLS certificate fingerprints, which allows the agent to accept and establish sessions with a malicious server. An attacker who controls the wired or wireless network can redirect traffic to a malicious server. The attacker can then use the agent’s built‑in command/file features to execute arbitrary commands as SYSTEM, granting full administrative control and the ability to disable endpoint protections or exfiltrate data.
Severity
HIGH
CVSS score
7.7
(v4.0)
Vulnerability status
Deferred
Source identifier
a14582b7-06f4-4d66-8e82-3d7ba3739e88
Published
2026-10-26 21:17:01.887000
Last modified
2026-10-27 16:04:22.707000
View original CVE JSON
{
"id": "CVE-2025-13833",
"sourceIdentifier": "a14582b7-06f4-4d66-8e82-3d7ba3739e88",
"published": "2026-10-26T21:17:01.887",
"lastModified": "2026-10-27T16:04:22.707",
"vulnStatus": "Deferred",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability exists in SecureConnector for Windows when the “Additional Appliance Connections” setting is enabled and the agent’s configuration file contains more than three trusted‑server entries. Some entries omit TLS certificate fingerprints, which allows the agent to accept and establish sessions with a malicious server. An attacker who controls the wired or wireless network can redirect traffic to a malicious server. The attacker can then use the agent’s built‑in command/file features to execute arbitrary commands as SYSTEM, granting full administrative control and the ability to disable endpoint protections or exfiltrate data."
}
],
"affected": [
{
"source": "a14582b7-06f4-4d66-8e82-3d7ba3739e88",
"affectedData": [
{
"vendor": "Forescout Technologies",
"product": "SecureConnector",
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"versions": [
{
"version": "0",
"lessThan": "11.3.20",
"versionType": "custom",
"status": "affected"
}
]
}
]
}
],
"metrics": {
"cvssMetricV40": [
{
"source": "a14582b7-06f4-4d66-8e82-3d7ba3739e88",
"type": "Secondary",
"cvssData": {
"version": "4.0",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"attackVector": "ADJACENT",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"confidentialityRequirement": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"availabilityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED"
}
}
]
},
"weaknesses": [
{
"source": "a14582b7-06f4-4d66-8e82-3d7ba3739e88",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-295"
}
]
}
],
"references": [
{
"url": "https://support.forescout.com",
"source": "a14582b7-06f4-4d66-8e82-3d7ba3739e88"
}
]
}