CVE-2025-36566
Full vulnerability record from the local CVENow database.
Description
Dell PowerProtect Data Domain with Data Domain Operating System (DD OS) of Feature Release versions 7.7.1.0 through 8.1.0.10, LTS2024 release Versions 7.13.1.0 through 7.13.1.25, LTS 2023 release versions 7.10.1.0 through 7.10.1.50, contain an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary command execution. Exploitation may allow privilege escalation to root.
Severity
MEDIUM
CVSS score
6.7
(v3.1)
Vulnerability status
Analyzed
Source identifier
Published
2025-10-07 20:15:33.953000
Last modified
2026-10-18 21:10:00.120000
View original CVE JSON
{
"id": "CVE-2025-36566",
"sourceIdentifier": "[email protected]",
"published": "2025-10-07T20:15:33.953",
"lastModified": "2026-10-18T21:10:00.120",
"vulnStatus": "Analyzed",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell PowerProtect Data Domain with Data Domain Operating System (DD OS) of Feature Release versions 7.7.1.0 through 8.1.0.10, LTS2024 release Versions 7.13.1.0 through 7.13.1.25, LTS 2023 release versions 7.10.1.0 through 7.10.1.50, contain an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary command execution. Exploitation may allow privilege escalation to root."
},
{
"lang": "es",
"value": "Dell PowerProtect Data Domain con Data Domain Operating System (DD OS) de las versiones Feature Release 7.7.1.0 a 8.1.0.10, versiones LTS2024 release 7.13.1.0 a 7.13.1.25, y versiones LTS 2023 release 7.10.1.0 a 7.10.1.50, contienen una vulnerabilidad de 'Neutralización Inadecuada de Elementos Especiales utilizados en un Comando del Sistema Operativo' ('Inyección de Comandos del Sistema Operativo'). Un atacante con altos privilegios y acceso local podría potencialmente explotar esta vulnerabilidad, lo que podría llevar a la ejecución arbitraria de comandos. La explotación podría permitir la escalada de privilegios a root."
}
],
"affected": [
{
"source": "[email protected]",
"affectedData": [
{
"vendor": "Dell",
"product": "PowerProtect Data Domain with Data Domain Operating System (DD OS) of Feature Release",
"defaultStatus": "unaffected",
"versions": [
{
"version": "7.7.1.0",
"lessThan": "8.3.0.10",
"versionType": "semver",
"status": "affected"
}
]
},
{
"vendor": "Dell",
"product": "PowerProtect Data Domain with Data Domain Operating System (DD OS) LTS2024",
"defaultStatus": "unaffected",
"versions": [
{
"version": "7.13.1.0",
"lessThan": "7.13.1.30",
"versionType": "semver",
"status": "affected"
}
]
},
{
"vendor": "Dell",
"product": "PowerProtect Data Domain with Data Domain Operating System (DD OS) LTS2023",
"defaultStatus": "unaffected",
"versions": [
{
"version": "7.10.1.0",
"lessThan": "7.10.1.60",
"versionType": "semver",
"status": "affected"
}
]
}
]
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "[email protected]",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 0.8,
"impactScore": 5.9
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"timestamp": "2025-10-08T03:55:28.400409Z",
"id": "CVE-2025-36566",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
]
},
"weaknesses": [
{
"source": "[email protected]",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*",
"versionStartIncluding": "7.7.1.0",
"versionEndExcluding": "7.10.1.60",
"matchCriteriaId": "F2389C08-162A-4D43-B1EA-D93D7DB51781"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*",
"versionStartIncluding": "7.13.1.0",
"versionEndExcluding": "7.13.1.30",
"matchCriteriaId": "5E7EC11C-C065-48D9-A036-5A17653D44EA"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*",
"versionStartIncluding": "8.0.0.0",
"versionEndExcluding": "8.3.0.10",
"matchCriteriaId": "FD518568-542A-420D-B0E6-6F35E127E5CE"
}
]
}
]
}
],
"references": [
{
"url": "https://www.dell.com/support/kbdoc/en-us/000348708/dsa-2025-159-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities",
"source": "[email protected]",
"tags": [
"Vendor Advisory"
]
}
]
}