← Back to CVE Explorer

CVE-2025-40818

Full vulnerability record from the local CVENow database.

Description

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP4). Affected applications contain private SSL/TLS keys on the server that are not properly protected allowing any user with server access to read these keys. This could allow an authenticated attacker to impersonate the server potentially enabling man-in-the-middle, traffic decryption or unauthorized access to services that trust these certificates.

Severity
LOW
CVSS score
3.3 (v3.1)
Vulnerability status
Analyzed
Source identifier
Published
2025-12-09 16:17:46.040000
Last modified
2026-10-23 22:10:00.160000
View original CVE JSON
{
  "id": "CVE-2025-40818",
  "sourceIdentifier": "[email protected]",
  "published": "2025-12-09T16:17:46.040",
  "lastModified": "2026-10-23T22:10:00.160",
  "vulnStatus": "Analyzed",
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP4). Affected applications contain private SSL/TLS keys on the server that are not properly protected allowing any user with server access to read these keys. This could allow an authenticated attacker to impersonate the server potentially enabling man-in-the-middle, traffic decryption or unauthorized access to services that trust these certificates."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad ha sido identificada en SINEMA Remote Connect Server (Todas las versiones anteriores a V3.2 SP4). Las aplicaciones afectadas contienen claves privadas SSL/TLS en el servidor que no están protegidas adecuadamente, permitiendo a cualquier usuario con acceso al servidor leer estas claves. Esto podría permitir a un atacante autenticado suplantar al servidor, lo que podría habilitar man-in-the-middle, el descifrado de tráfico o el acceso no autorizado a servicios que confían en estos certificados."
    }
  ],
  "affected": [
    {
      "source": "[email protected]",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "SINEMA Remote Connect Server",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "lessThan": "V3.2 SP4",
              "versionType": "custom",
              "status": "affected"
            }
          ]
        }
      ]
    }
  ],
  "metrics": {
    "cvssMetricV31": [
      {
        "source": "[email protected]",
        "type": "Secondary",
        "cvssData": {
          "version": "3.1",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
          "baseScore": 3.3,
          "baseSeverity": "LOW",
          "attackVector": "LOCAL",
          "attackComplexity": "LOW",
          "privilegesRequired": "LOW",
          "userInteraction": "NONE",
          "scope": "UNCHANGED",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "availabilityImpact": "NONE"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 1.4
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "timestamp": "2025-12-09T16:36:34.247093Z",
          "id": "CVE-2025-40818",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "role": "CISA Coordinator",
          "version": "2.0.3"
        }
      }
    ]
  },
  "weaknesses": [
    {
      "source": "[email protected]",
      "type": "Secondary",
      "description": [
        {
          "lang": "en",
          "value": "CWE-732"
        }
      ]
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "operator": "OR",
          "negate": false,
          "cpeMatch": [
            {
              "vulnerable": true,
              "criteria": "cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*",
              "versionEndExcluding": "3.2",
              "matchCriteriaId": "BA2839E7-E397-4D69-865B-439F0017D540"
            },
            {
              "vulnerable": true,
              "criteria": "cpe:2.3:a:siemens:sinema_remote_connect_server:3.2:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "A5A387A4-6899-4756-9EAA-ADBC636F8CF4"
            },
            {
              "vulnerable": true,
              "criteria": "cpe:2.3:a:siemens:sinema_remote_connect_server:3.2:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "9FAB8933-0A70-437C-9190-24B03C96E4C6"
            },
            {
              "vulnerable": true,
              "criteria": "cpe:2.3:a:siemens:sinema_remote_connect_server:3.2:sp3:*:*:*:*:*:*",
              "matchCriteriaId": "866C3491-9238-436C-A096-B52FD8B4E659"
            }
          ]
        }
      ]
    }
  ],
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-626856.html",
      "source": "[email protected]",
      "tags": [
        "Vendor Advisory"
      ]
    }
  ]
}