A vulnerability has been identified in Siemens Software Center (All versions < V3.5), Solid Edge SE2025 (All versions < V225.0 Update 10). The affected application is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code via placing a crafted DLL file on the system.

Severity
HIGH
CVSS score
8.5 (v4.0)
Vulnerability status
Deferred
Source identifier
Published
2025-11-11 21:15:38.627000
Last modified
2026-10-23 22:10:00.160000
View original CVE JSON
{
  "id": "CVE-2025-40827",
  "sourceIdentifier": "[email protected]",
  "published": "2025-11-11T21:15:38.627",
  "lastModified": "2026-10-23T22:10:00.160",
  "vulnStatus": "Deferred",
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Siemens Software Center (All versions < V3.5), Solid Edge SE2025 (All versions < V225.0 Update 10). The affected application is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code via placing a crafted DLL file on the system."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en Siemens Software Center (Todas las versiones anteriores a V3.5), Solid Edge SE2025 (Todas las versiones anteriores a V225.0 Update 10). La aplicación afectada es vulnerable a secuestro de DLL. Esto podría permitir a un atacante ejecutar código arbitrario mediante la colocación de un archivo DLL manipulado en el sistema."
    }
  ],
  "affected": [
    {
      "source": "[email protected]",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "Siemens Software Center",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "lessThan": "V3.5",
              "versionType": "custom",
              "status": "affected"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Solid Edge SE2025",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "lessThan": "V225.0 Update 10",
              "versionType": "custom",
              "status": "affected"
            }
          ]
        }
      ]
    }
  ],
  "metrics": {
    "cvssMetricV40": [
      {
        "source": "[email protected]",
        "type": "Secondary",
        "cvssData": {
          "version": "4.0",
          "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "baseScore": 8.5,
          "baseSeverity": "HIGH",
          "attackVector": "LOCAL",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "NONE",
          "userInteraction": "PASSIVE",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnAvailabilityImpact": "HIGH",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "subAvailabilityImpact": "NONE",
          "exploitMaturity": "NOT_DEFINED",
          "confidentialityRequirement": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "valueDensity": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "source": "[email protected]",
        "type": "Secondary",
        "cvssData": {
          "version": "3.1",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "attackVector": "LOCAL",
          "attackComplexity": "LOW",
          "privilegesRequired": "NONE",
          "userInteraction": "REQUIRED",
          "scope": "UNCHANGED",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "availabilityImpact": "HIGH"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "timestamp": "2025-11-12T14:11:39.704790Z",
          "id": "CVE-2025-40827",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "role": "CISA Coordinator",
          "version": "2.0.3"
        }
      }
    ]
  },
  "weaknesses": [
    {
      "source": "[email protected]",
      "type": "Secondary",
      "description": [
        {
          "lang": "en",
          "value": "CWE-427"
        }
      ]
    }
  ],
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-365596.html",
      "source": "[email protected]"
    }
  ]
}