CVE-2025-50526
Full vulnerability record from the local CVENow database.
Description
Netgear EX8000 V1.0.0.126 was discovered to contain a command injection vulnerability via the switch_status function.
Severity
CRITICAL
CVSS score
9.8
(v3.1)
Vulnerability status
Analyzed
Source identifier
Published
2025-12-23 16:16:22.620000
Last modified
2026-10-26 21:10:00.170000
View original CVE JSON
{
"id": "CVE-2025-50526",
"sourceIdentifier": "[email protected]",
"published": "2025-12-23T16:16:22.620",
"lastModified": "2026-10-26T21:10:00.170",
"vulnStatus": "Analyzed",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Netgear EX8000 V1.0.0.126 was discovered to contain a command injection vulnerability via the switch_status function."
},
{
"lang": "es",
"value": "Se descubrió que Netgear EX8000 V1.0.0.126 contiene una vulnerabilidad de inyección de comandos a través de la función switch_status."
}
],
"affected": [
{
"source": "[email protected]",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"version": "n/a",
"status": "affected"
}
]
}
]
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"timestamp": "2025-12-23T16:48:27.781776Z",
"id": "CVE-2025-50526",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
]
},
"weaknesses": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-77"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:ex8000_firmware:1.0.0.126:*:*:*:*:*:*:*",
"matchCriteriaId": "F2BA94AB-B85E-4EA2-9DF0-CDBED59930EA"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:ex8000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8D9781C9-799A-4BDA-A027-987627A01633"
}
]
}
]
}
],
"references": [
{
"url": "https://github.com/JZP018/vuln03/blob/main/netgear/EX8000/cve-netgear_EX8000_CI_switch_status.pdf",
"source": "[email protected]",
"tags": [
"Broken Link"
]
},
{
"url": "https://github.com/JZP018/vuln03/blob/main/netgear/EX8000/netgear_EX8000_CI_switch_status.mp4",
"source": "[email protected]",
"tags": [
"Broken Link"
]
}
]
}