Description

A vulnerability was identified in certain UniFi Talk devices where internal debugging functionality remained unintentionally enabled. This issue could allow an attacker with access to the UniFi Talk management network to invoke internal debug operations through the device API. Affected Products: UniFi Talk Touch (Version 1.21.16 and earlier) UniFi Talk Touch Max (Version 2.21.22 and earlier) UniFi Talk G3 Phones (Version 3.21.26 and earlier) Mitigation: Update the UniFi Talk Touch to Version 1.21.17 or later. Update the UniFi Talk Touch Max to Version 2.21.23 or later. Update the UniFi Talk G3 Phones to Version 3.21.27 or later.

Severity
HIGH
CVSS score
7.3 (v3.1)
Vulnerability status
Deferred
Source identifier
Published
2025-10-31 00:15:36.773000
Last modified
2026-10-18 21:10:00.120000
View original CVE JSON
{
  "id": "CVE-2025-52663",
  "sourceIdentifier": "[email protected]",
  "published": "2025-10-31T00:15:36.773",
  "lastModified": "2026-10-18T21:10:00.120",
  "vulnStatus": "Deferred",
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability was identified in certain UniFi Talk devices where internal debugging functionality remained unintentionally enabled. This issue could allow an attacker with access to the UniFi Talk management network to invoke internal debug operations through the device API.\r\n\r\n\r\nAffected Products:\r\nUniFi Talk Touch (Version 1.21.16 and earlier) \r\nUniFi Talk Touch Max (Version 2.21.22 and earlier) \r\nUniFi Talk G3 Phones (Version 3.21.26 and earlier) \r\n \r\nMitigation:\r\nUpdate the UniFi Talk Touch to Version 1.21.17 or later.\r\nUpdate the UniFi Talk Touch Max to Version 2.21.23 or later.\r\nUpdate the UniFi Talk G3 Phones to Version 3.21.27 or later."
    },
    {
      "lang": "es",
      "value": "Se identificó una vulnerabilidad en ciertos dispositivos UniFi Talk donde la funcionalidad de depuración interna permaneció habilitada de forma no intencionada. Este problema podría permitir a un atacante con acceso a la red de gestión de UniFi Talk invocar operaciones de depuración internas a través de la API del dispositivo.\n\nProductos Afectados:\nUniFi Talk Touch (Versión 1.21.16 y anteriores)\nUniFi Talk Touch Max (Versión 2.21.22 y anteriores)\nTeléfonos UniFi Talk G3 (Versión 3.21.26 y anteriores)\n\nMitigación:\nActualice el UniFi Talk Touch a la Versión 1.21.17 o posterior.\nActualice el UniFi Talk Touch Max a la Versión 2.21.23 o posterior.\nActualice los Teléfonos UniFi Talk G3 a la Versión 3.21.27 o posterior."
    }
  ],
  "affected": [
    {
      "source": "[email protected]",
      "affectedData": [
        {
          "vendor": "Ubiquiti Inc",
          "product": "UniFi Talk Touch",
          "defaultStatus": "affected",
          "versions": [
            {
              "version": "1.21.17",
              "lessThan": "1.21.17",
              "versionType": "semver",
              "status": "unaffected"
            }
          ]
        },
        {
          "vendor": "Ubiquiti Inc",
          "product": "UniFi Talk Touch Max",
          "defaultStatus": "affected",
          "versions": [
            {
              "version": "2.21.23",
              "lessThan": "2.21.23",
              "versionType": "semver",
              "status": "unaffected"
            }
          ]
        },
        {
          "vendor": "Ubiquiti Inc",
          "product": "UniFi Talk G3 Phones",
          "defaultStatus": "affected",
          "versions": [
            {
              "version": "3.21.27",
              "lessThan": "3.21.27",
              "versionType": "semver",
              "status": "unaffected"
            }
          ]
        }
      ]
    }
  ],
  "metrics": {
    "cvssMetricV31": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary",
        "cvssData": {
          "version": "3.1",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
          "baseScore": 7.3,
          "baseSeverity": "HIGH",
          "attackVector": "NETWORK",
          "attackComplexity": "LOW",
          "privilegesRequired": "NONE",
          "userInteraction": "NONE",
          "scope": "UNCHANGED",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "availabilityImpact": "LOW"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.4
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "timestamp": "2025-11-03T15:36:11.348827Z",
          "id": "CVE-2025-52663",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "role": "CISA Coordinator",
          "version": "2.0.3"
        }
      }
    ]
  },
  "weaknesses": [
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary",
      "description": [
        {
          "lang": "en",
          "value": "CWE-489"
        }
      ]
    }
  ],
  "references": [
    {
      "url": "https://community.ui.com/releases/Security-Advisory-Bulletin-055-055/9b65527b-489c-4f16-ac34-2b887754db1e",