← Back to CVE Explorer

CVE-2025-57130

Full vulnerability record from the local CVENow database.

Description

An Incorrect Access Control vulnerability in the user management component of ZwiiCMS up to v13.6.07 allows a remote, authenticated attacker to escalate their privileges. By sending a specially crafted HTTP request, a low-privilege user can access and modify the profile data of any other user, including administrators.

Severity
HIGH
CVSS score
8.8 (v3.1)
Vulnerability status
Modified
Source identifier
Published
2025-11-05 16:15:40.203000
Last modified
2026-11-05 14:10:00.273000
View original CVE JSON
{
  "id": "CVE-2025-57130",
  "sourceIdentifier": "[email protected]",
  "published": "2025-11-05T16:15:40.203",
  "lastModified": "2026-11-05T14:10:00.273",
  "vulnStatus": "Modified",
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An Incorrect Access Control vulnerability in the user management component of ZwiiCMS up to v13.6.07 allows a remote, authenticated attacker to escalate their privileges. By sending a specially crafted HTTP request, a low-privilege user can access and modify the profile data of any other user, including administrators."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad de control de acceso incorrecto en el componente de gestión de usuarios de ZwiiCMS hasta la v13.6.07 permite a un atacante remoto y autenticado escalar sus privilegios. Al enviar una solicitud HTTP especialmente diseñada, un usuario de bajo privilegio puede acceder y modificar los datos de perfil de cualquier otro usuario, incluidos los administradores."
    }
  ],
  "affected": [
    {
      "source": "[email protected]",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "version": "n/a",
              "status": "affected"
            }
          ]
        }
      ]
    }
  ],
  "metrics": {
    "cvssMetricV31": [
      {
        "source": "[email protected]",
        "type": "Secondary",
        "cvssData": {
          "version": "3.1",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
          "baseScore": 8.3,
          "baseSeverity": "HIGH",
          "attackVector": "NETWORK",
          "attackComplexity": "LOW",
          "privilegesRequired": "LOW",
          "userInteraction": "NONE",
          "scope": "UNCHANGED",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "availabilityImpact": "LOW"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.5
      },
      {
        "source": "[email protected]",
        "type": "Primary",
        "cvssData": {
          "version": "3.1",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "attackVector": "NETWORK",
          "attackComplexity": "LOW",
          "privilegesRequired": "LOW",
          "userInteraction": "NONE",
          "scope": "UNCHANGED",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "availabilityImpact": "HIGH"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "timestamp": "2025-11-05T16:19:54.931002Z",
          "id": "CVE-2025-57130",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "role": "CISA Coordinator",
          "version": "2.0.3"
        }
      }
    ]
  },
  "weaknesses": [
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary",
      "description": [
        {
          "lang": "en",
          "value": "CWE-284"
        }
      ]
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "operator": "OR",
          "negate": false,
          "cpeMatch": [
            {
              "vulnerable": true,
              "criteria": "cpe:2.3:a:zwiicms:zwiicms:*:*:*:*:*:*:*:*",
              "versionEndIncluding": "13.6.07",
              "matchCriteriaId": "5FE3AA50-5558-450B-ADF7-E28D6C26E138"
            }
          ]
        }
      ]
    }
  ],
  "references": [
    {
      "url": "https://blog.nivel4.com/noticias/cve-2025-57130-especialistas-de-nivel4-identifican-falla-de-alta-severidad-en-gestor-de-contenidos",
      "source": "[email protected]",
      "tags": [
        "Third Party Advisory"
      ]
    }
  ]
}