Description
An issue was discovered in bridgetech VB288 Objective QoE Content Extractor, firmware version 5.6.0-8, allowing attackers to gain sensitive information such as administrator passwords via the /probe/core/setup/passwd endpoint.
Severity
HIGH
CVSS score
7.5
(v3.1)
Vulnerability status
Analyzed
Source identifier
Published
2025-11-19 18:15:48.933000
Last modified
2026-11-05 13:10:00.180000
View original CVE JSON
{
"id": "CVE-2025-63208",
"sourceIdentifier": "[email protected]",
"published": "2025-11-19T18:15:48.933",
"lastModified": "2026-11-05T13:10:00.180",
"vulnStatus": "Analyzed",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in bridgetech VB288 Objective QoE Content Extractor, firmware version 5.6.0-8, allowing attackers to gain sensitive information such as administrator passwords via the /probe/core/setup/passwd endpoint."
},
{
"lang": "es",
"value": "Se descubrió un problema en bridgetech VB288 Objective QoE Content Extractor, versión de firmware 5.6.0-8, permitiendo a los atacantes obtener información sensible como contraseñas de administrador a través del endpoint /probe/core/setup/passwd."
}
],
"affected": [
{
"source": "[email protected]",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"version": "n/a",
"status": "affected"
}
]
}
]
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"timestamp": "2025-11-20T15:35:37.642279Z",
"id": "CVE-2025-63208",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
]
},
"weaknesses": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-312"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:bridgetech:vb288_firmware:5.6.0-8:*:*:*:*:*:*:*",
"matchCriteriaId": "5305127F-A790-414E-841B-EFB08726E98F"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:bridgetech:vb288:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8BC8CF9F-7583-4111-8FAE-C9F2B6F726DF"
}
]
}
]
}
],
"references": [
{
"url": "https://bridgetech.tv/",
"source": "[email protected]",
"tags": [
"Product"
]
},
{
"url": "https://github.com/shiky8/my--cve-vulnerability-research/tree/main/CVE-2025-63208_bridgetech%20VB288%20Information%20Disclosure",
"source": "[email protected]",
"tags": [
"Exploit",
"Third Party Advisory"
]
}
]
}