CVE-2025-9996
Full vulnerability record from the local CVENow database.
Description
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause the execution of any shell command when executing a netstat command using BLMon Console in an SSH session.
Severity
MEDIUM
CVSS score
5.8
(v4.0)
Vulnerability status
Deferred
Source identifier
Published
2025-09-09 21:15:39.893000
Last modified
2026-10-18 21:10:00.120000
View original CVE JSON
{
"id": "CVE-2025-9996",
"sourceIdentifier": "[email protected]",
"published": "2025-09-09T21:15:39.893",
"lastModified": "2026-10-18T21:10:00.120",
"vulnStatus": "Deferred",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause the execution of any shell command when executing a netstat command using BLMon Console in an SSH session."
},
{
"lang": "es",
"value": "CWE-78: Existe una vulnerabilidad de Neutralización Incorrecta de Elementos Especiales utilizados en un Comando del SO ('Inyección de Comandos del SO') que podría causar la ejecución de cualquier comando de shell al ejecutar un comando netstat usando la Consola BLMon en una sesión SSH."
}
],
"affected": [
{
"source": "[email protected]",
"affectedData": [
{
"vendor": "Schneider Electric",
"product": "Saitel DR RTU",
"defaultStatus": "unaffected",
"versions": [
{
"version": "all versions",
"lessThanOrEqual": "11.06.29",
"versionType": "version",
"status": "affected"
}
]
},
{
"vendor": "Schneider Electric",
"product": "Saitel DP RTU",
"defaultStatus": "unaffected",
"versions": [
{
"version": "all versions",
"lessThanOrEqual": "11.06.33",
"versionType": "version",
"status": "affected"
}
]
}
]
}
],
"metrics": {
"cvssMetricV40": [
{
"source": "[email protected]",
"type": "Secondary",
"cvssData": {
"version": "4.0",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "LOW",
"vulnAvailabilityImpact": "LOW",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"confidentialityRequirement": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"availabilityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED"
}
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"timestamp": "2025-09-10T20:26:36.121564Z",
"id": "CVE-2025-9996",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
]
},
"weaknesses": [
{
"source": "[email protected]",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-252-02.pdf",
"source": "[email protected]"
}
]
}