CVE-2025-9997
Full vulnerability record from the local CVENow database.
Description
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause command injection in BLMon that is executed in the operating system console when in a SSH session.
Severity
MEDIUM
CVSS score
5.8
(v4.0)
Vulnerability status
Deferred
Source identifier
Published
2025-09-09 22:15:34.833000
Last modified
2026-10-18 21:10:00.120000
View original CVE JSON
{
"id": "CVE-2025-9997",
"sourceIdentifier": "[email protected]",
"published": "2025-09-09T22:15:34.833",
"lastModified": "2026-10-18T21:10:00.120",
"vulnStatus": "Deferred",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause command injection in BLMon that is executed in the operating system console when in a SSH session."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad CWE-78: Neutralización Incorrecta de Elementos Especiales utilizados en un Comando de SO ('Inyección de Comandos del SO') que podría causar inyección de comandos en BLMon que se ejecuta en la consola del sistema operativo cuando está en una sesión SSH."
}
],
"affected": [
{
"source": "[email protected]",
"affectedData": [
{
"vendor": "Schneider Electric",
"product": "Saitel DR RTU",
"defaultStatus": "unaffected",
"versions": [
{
"version": "all versions",
"lessThanOrEqual": "11.06.29",
"versionType": "version",
"status": "affected"
}
]
},
{
"vendor": "Schneider Electric",
"product": "Saitel DP RTU",
"defaultStatus": "unaffected",
"versions": [
{
"version": "all versions",
"lessThanOrEqual": "11.06.33",
"versionType": "version",
"status": "affected"
}
]
}
]
}
],
"metrics": {
"cvssMetricV40": [
{
"source": "[email protected]",
"type": "Secondary",
"cvssData": {
"version": "4.0",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "LOW",
"vulnAvailabilityImpact": "LOW",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"confidentialityRequirement": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"availabilityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED"
}
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"timestamp": "2025-09-10T19:34:13.130524Z",
"id": "CVE-2025-9997",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
]
},
"weaknesses": [
{
"source": "[email protected]",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-252-02.pdf",
"source": "[email protected]"
}
]
}