CVE-2026-0646
Full vulnerability record from the local CVENow database.
Description
A denial-of-service security issue exists within the 1794-AENTR adapter due to improper memory handling of CIP protocol requests. This vulnerability can result in the adapter faulting and losing connection to its associated I/O modules, requiring a manual reset to recover.
Severity
HIGH
CVSS score
8.7
(v4.0)
Vulnerability status
Awaiting Analysis
Source identifier
Published
2026-06-16 15:16:33.567000
Last modified
2026-10-26 12:10:00.130000
View original CVE JSON
{
"id": "CVE-2026-0646",
"sourceIdentifier": "[email protected]",
"published": "2026-06-16T15:16:33.567",
"lastModified": "2026-10-26T12:10:00.130",
"vulnStatus": "Awaiting Analysis",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A denial-of-service security issue exists within the 1794-AENTR adapter due to improper memory handling of CIP protocol requests. This vulnerability can result in the adapter faulting and losing connection to its associated I/O modules, requiring a manual reset to recover."
},
{
"lang": "es",
"value": "Un problema de seguridad de denegación de servicio existe dentro del adaptador 1794-AENTR debido al manejo inadecuado de la memoria de las solicitudes del protocolo CIP. Esta vulnerabilidad puede resultar en que el adaptador falle y pierda la conexión con sus módulos de E/S asociados, requiriendo un reinicio manual para recuperarse."
}
],
"affected": [
{
"source": "[email protected]",
"affectedData": [
{
"vendor": "Rockwell Automation",
"product": "FLEX I/O EtherNet/IP Adapters",
"defaultStatus": "unaffected",
"versions": [
{
"version": "2.012",
"versionType": "custom",
"status": "affected"
}
]
}
]
}
],
"metrics": {
"cvssMetricV40": [
{
"source": "[email protected]",
"type": "Secondary",
"cvssData": {
"version": "4.0",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"confidentialityRequirement": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"availabilityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED"
}
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"timestamp": "2026-06-16T15:24:26.161390Z",
"id": "CVE-2026-0646",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
]
},
"weaknesses": [
{
"source": "[email protected]",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-401"
}
]
}
],
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1775.html",
"source": "[email protected]"
}
]
}