CVE-2026-103405
Full vulnerability record from the local CVENow database.
Description
An Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') vulnerability in the web server in Juniper Networks Session Smart Router and Session Smart Conductor allows an attacker to inject arbitrary HTTP headers via unsanitized request body parameters.
Severity
MEDIUM
CVSS score
5.8
(v3.1)
Vulnerability status
Awaiting Analysis
Source identifier
Published
2026-10-28 17:17:25.320000
Last modified
2026-10-28 17:17:25.560000
View original CVE JSON
{
"id": "CVE-2026-103405",
"sourceIdentifier": "[email protected]",
"published": "2026-10-28T17:17:25.320",
"lastModified": "2026-10-28T17:17:25.560",
"vulnStatus": "Awaiting Analysis",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') vulnerability in the web server in Juniper Networks Session Smart Router and Session Smart Conductor allows an attacker to inject arbitrary HTTP headers via unsanitized request body parameters."
}
],
"affected": [
{
"source": "[email protected]",
"affectedData": [
{
"vendor": "Juniper Networks",
"product": "Session Smart Router",
"defaultStatus": "unaffected",
"versions": [
{
"version": "0",
"lessThan": "7.0.5",
"versionType": "custom",
"status": "affected"
},
{
"version": "7.1.0",
"lessThan": "7.1.7",
"versionType": "custom",
"status": "affected"
},
{
"version": "7.2.0",
"lessThan": "7.2.3",
"versionType": "custom",
"status": "affected"
}
]
},
{
"vendor": "Juniper Networks",
"product": "Session Smart Conductor",
"defaultStatus": "unaffected",
"versions": [
{
"version": "0",
"lessThan": "7.0.5",
"versionType": "custom",
"status": "affected"
},
{
"version": "7.1.0",
"lessThan": "7.1.7",
"versionType": "custom",
"status": "affected"
},
{
"version": "7.2.0",
"lessThan": "7.2.3",
"versionType": "custom",
"status": "affected"
}
]
}
]
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "[email protected]",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "CHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4
}
]
},
"weaknesses": [
{
"source": "[email protected]",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-74"
}
]
}
],
"references": [
{
"url": "https://supportportal.juniper.net/JSA112183",
"source": "[email protected]"
}
]
}