CVE-2026-111594
Full vulnerability record from the local CVENow database.
Description
InterSystems IRIS for Health has TLS/SSL encryption turned off by default, which may enable an attacker to view transmitted data and use that data to log into the device.
Severity
CRITICAL
CVSS score
9.2
(v4.0)
Vulnerability status
Awaiting Analysis
Source identifier
Published
2026-10-22 22:18:01.060000
Last modified
2026-10-23 19:43:46.190000
View original CVE JSON
{
"id": "CVE-2026-111594",
"sourceIdentifier": "[email protected]",
"published": "2026-10-22T22:18:01.060",
"lastModified": "2026-10-23T19:43:46.190",
"vulnStatus": "Awaiting Analysis",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "InterSystems IRIS for Health has TLS/SSL encryption turned off by default, which may enable an attacker to view transmitted data and use that data to log into the device."
}
],
"affected": [
{
"source": "[email protected]",
"affectedData": [
{
"vendor": "InterSystems",
"product": "IRIS for Health",
"defaultStatus": "unaffected",
"versions": [
{
"version": "2026.2.0.221",
"status": "affected"
},
{
"version": "2026.1.0.235",
"status": "affected"
},
{
"version": "2025.3.0.226",
"status": "affected"
}
]
}
]
}
],
"metrics": {
"cvssMetricV40": [
{
"source": "[email protected]",
"type": "Secondary",
"cvssData": {
"version": "4.0",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"baseScore": 9.2,
"baseSeverity": "CRITICAL",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"confidentialityRequirement": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"availabilityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED"
}
}
],
"cvssMetricV31": [
{
"source": "[email protected]",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "HIGH",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 2.2,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "[email protected]",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-319"
}
]
}
],
"references": [
{
"url": "https://docs.intersystems.com/irislatest/csp/docbook/DocBook.UI.Page.cls?KEY=GSA_manage_superserver",
"source": "[email protected]"
},
{
"url": "https://docs.intersystems.com/irislatest/csp/docbook/DocBook.UI.Page.cls?KEY=ROARS_gsecuring_checklist",
"source": "[email protected]"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsma-26-295-01.json",
"source": "[email protected]"
},
{
"url": "https://wrc.intersystems.com",
"source": "[email protected]"
},
{
"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-295-01",
"source": "[email protected]"
}
]
}