CVE-2026-112172
Full vulnerability record from the local CVENow database.
Description
CGM XDent and XMedical expose PHP synchronization endpoints that allow unauthenticated attackers to manipulate session variables and execute arbitrary SQL queries against backend MySQL databases.
Severity
HIGH
CVSS score
8.1
(v4.0)
Vulnerability status
Received
Source identifier
a6d3dc9e-0591-4a13-bce7-0f5b31ff6158
Published
2026-11-09 12:16:35.170000
Last modified
2026-11-09 12:16:35.170000
View original CVE JSON
{
"id": "CVE-2026-112172",
"sourceIdentifier": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"published": "2026-11-09T12:16:35.170",
"lastModified": "2026-11-09T12:16:35.170",
"vulnStatus": "Received",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "CGM XDent and XMedical expose PHP synchronization endpoints that allow unauthenticated attackers to manipulate session variables and execute arbitrary SQL queries against backend MySQL databases."
}
],
"affected": [
{
"source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"affectedData": [
{
"vendor": "CompuGroup Medical",
"product": "XDent",
"defaultStatus": "unaffected",
"versions": [
{
"version": "0",
"lessThan": "4.4.0",
"versionType": "semver",
"status": "affected"
}
]
},
{
"vendor": "CompuGroup Medical",
"product": "XMedical",
"defaultStatus": "unaffected",
"versions": [
{
"version": "0",
"lessThan": "4.4.0",
"versionType": "semver",
"status": "affected"
}
]
}
]
}
],
"metrics": {
"cvssMetricV40": [
{
"source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"type": "Secondary",
"cvssData": {
"version": "4.0",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:X/V:X/RE:X/U:X",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "UNREPORTED",
"confidentialityRequirement": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"availabilityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "YES",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED"
}
}
]
},
"weaknesses": [
{
"source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-89"
}
]
}
],
"references": [
{
"url": "https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical",
"source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158"
},
{
"url": "https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html",
"source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158"
}
]
}