CVE-2026-116486
Full vulnerability record from the local CVENow database.
Description
Objenesis before 3.6 contains a type confusion vulnerability that allows code in one class loader to substitute objects into another by exploiting instantiator caching keyed on class name. When a shared ObjenesisStd instance caches instantiators by clazz.getName() in ObjenesisBase.getInstantiatorOf(), same-named classes collide, causing newInstance() to return wrong-class objects and ClassCastException failures.
Severity
LOW
CVSS score
2.0
(v4.0)
Vulnerability status
Awaiting Analysis
Source identifier
Published
2026-10-26 14:16:37.200000
Last modified
2026-10-26 18:39:42.503000
View original CVE JSON
{
"id": "CVE-2026-116486",
"sourceIdentifier": "[email protected]",
"published": "2026-10-26T14:16:37.200",
"lastModified": "2026-10-26T18:39:42.503",
"vulnStatus": "Awaiting Analysis",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Objenesis before 3.6 contains a type confusion vulnerability that allows code in one class loader to substitute objects into another by exploiting instantiator caching keyed on class name. When a shared ObjenesisStd instance caches instantiators by clazz.getName() in ObjenesisBase.getInstantiatorOf(), same-named classes collide, causing newInstance() to return wrong-class objects and ClassCastException failures."
}
],
"affected": [
{
"source": "[email protected]",
"affectedData": [
{
"vendor": "easymock",
"product": "objenesis",
"defaultStatus": "unaffected",
"packageURL": "pkg:maven/org.objenesis/objenesis",
"versions": [
{
"version": "0",
"lessThan": "3.6",
"versionType": "custom",
"status": "affected"
},
{
"version": "3.6",
"versionType": "custom",
"status": "unaffected"
}
]
}
]
}
],
"metrics": {
"cvssMetricV40": [
{
"source": "[email protected]",
"type": "Secondary",
"cvssData": {
"version": "4.0",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"baseScore": 2.0,
"baseSeverity": "LOW",
"attackVector": "LOCAL",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnAvailabilityImpact": "LOW",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"confidentialityRequirement": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"availabilityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED"
}
}
],
"cvssMetricV31": [
{
"source": "[email protected]",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:L",
"baseScore": 4.5,
"baseSeverity": "MEDIUM",
"attackVector": "LOCAL",
"attackComplexity": "HIGH",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"availabilityImpact": "LOW"
},
"exploitabilityScore": 1.0,
"impactScore": 3.4
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"timestamp": "2026-10-26T15:38:10.344457Z",
"id": "CVE-2026-116486",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
]
},
"weaknesses": [
{
"source": "[email protected]",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-386"
}
]
}
],
"references": [
{
"url": "https://github.com/easymock/objenesis",
"source": "[email protected]"
},
{
"url": "https://github.com/easymock/objenesis/blob/fb36e5c377ed1bf57a18386fa79d2eed4ddfcfac/main/src/main/java/org/objenesis/ObjenesisBase.java#L92-L95",
"source": "[email protected]"
},
{
"url": "https://github.com/easymock/objenesis/commit/40f90f435a06b16af74a7398f0007faeaa52c00c",
"source": "[email protected]"
},
{
"url": "https://github.com/easymock/objenesis/security/advisories/GHSA-743r-26gf-97ff",
"source": "[email protected]"
},
{
"url": "https://www.vulncheck.com/advisories/objenesis-before-3.6-type-confusion-via-class-name-instantiator-cache",
"source": "[email protected]"
}
]
}