CVE-2026-118464
Full vulnerability record from the local CVENow database.
Description
Shared cryptographic services use fixed vendor-wide secrets, deterministic IVs, null salts, and reversible transformations to protect credentials, IPC data, configuration values, and clinical fields.
Severity
MEDIUM
CVSS score
5.8
(v4.0)
Vulnerability status
Received
Source identifier
a6d3dc9e-0591-4a13-bce7-0f5b31ff6158
Published
2026-11-09 12:16:37.270000
Last modified
2026-11-09 12:16:37.270000
View original CVE JSON
{
"id": "CVE-2026-118464",
"sourceIdentifier": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"published": "2026-11-09T12:16:37.270",
"lastModified": "2026-11-09T12:16:37.270",
"vulnStatus": "Received",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Shared cryptographic services use fixed vendor-wide secrets, deterministic IVs, null salts, and reversible transformations to protect credentials, IPC data, configuration values, and clinical fields."
}
],
"affected": [
{
"source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"affectedData": [
{
"vendor": "CompuGroup Medical",
"product": "Infantia",
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.common",
"versions": [
{
"version": "0",
"lessThanOrEqual": "5.1.1",
"versionType": "semver",
"status": "affected"
}
]
},
{
"vendor": "CompuGroup Medical",
"product": "Profim",
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.common",
"versions": [
{
"version": "0",
"lessThanOrEqual": "5.1.1",
"versionType": "semver",
"status": "affected"
}
]
},
{
"vendor": "CompuGroup Medical",
"product": "Venere",
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.common",
"versions": [
{
"version": "0",
"lessThanOrEqual": "5.1.1",
"versionType": "semver",
"status": "affected"
}
]
},
{
"vendor": "CompuGroup Medical",
"product": "Phronesis",
"defaultStatus": "unknown",
"packageName": "cgm.it.ais.common",
"versions": [
{
"version": "0",
"lessThanOrEqual": "5.1.1",
"versionType": "semver",
"status": "affected"
}
]
}
]
}
],
"metrics": {
"cvssMetricV40": [
{
"source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"type": "Secondary",
"cvssData": {
"version": "4.0",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "UNREPORTED",
"confidentialityRequirement": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"availabilityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED"
}
}
]
},
"weaknesses": [
{
"source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-321"
}
]
}
],
"references": [
{
"url": "https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical",
"source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158"
},
{
"url": "https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html",
"source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158"
}
]
}