← Back to CVE Explorer

CVE-2026-118605

Full vulnerability record from the local CVENow database.

Description

Alpine iLX-F511 prh_sdp_service_search_decode Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Alpine iLX-F511 devices. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability. The specific flaw exists within the prh_sdp_service_search_decode function. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-29069.

Severity
HIGH
CVSS score
8.0 (v3.0)
Vulnerability status
Deferred
Source identifier
Published
2026-10-28 17:18:27.560000
Last modified
2026-10-29 15:20:59.370000
View original CVE JSON
{
  "id": "CVE-2026-118605",
  "sourceIdentifier": "[email protected]",
  "published": "2026-10-28T17:18:27.560",
  "lastModified": "2026-10-29T15:20:59.370",
  "vulnStatus": "Deferred",
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Alpine iLX-F511 prh_sdp_service_search_decode Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Alpine iLX-F511 devices. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability.\n\nThe specific flaw exists within the prh_sdp_service_search_decode function. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-29069."
    }
  ],
  "affected": [
    {
      "source": "[email protected]",
      "affectedData": [
        {
          "vendor": "Alpine",
          "product": "iLX-F511",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "7.0.000",
              "status": "affected"
            }
          ]
        }
      ]
    }
  ],
  "metrics": {
    "cvssMetricV30": [
      {
        "source": "[email protected]",
        "type": "Secondary",
        "cvssData": {
          "version": "3.0",
          "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "baseScore": 8.0,
          "baseSeverity": "HIGH",
          "attackVector": "ADJACENT_NETWORK",
          "attackComplexity": "LOW",
          "privilegesRequired": "NONE",
          "userInteraction": "REQUIRED",
          "scope": "UNCHANGED",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "availabilityImpact": "HIGH"
        },
        "exploitabilityScore": 2.1,
        "impactScore": 5.9
      }
    ]
  },
  "weaknesses": [
    {
      "source": "[email protected]",
      "type": "Primary",
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ]
    }
  ],
  "references": [
    {
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-26-823/",
      "source": "[email protected]"
    }
  ]
}