CVE-2026-118791
Full vulnerability record from the local CVENow database.
Description
The application implements software update functionality without adequate authenticity and integrity validation, allowing update packages to be accepted without sufficient cryptographic verification.
Severity
HIGH
CVSS score
7.2
(v4.0)
Vulnerability status
Received
Source identifier
a6d3dc9e-0591-4a13-bce7-0f5b31ff6158
Published
2026-11-09 13:17:05.337000
Last modified
2026-11-09 13:17:05.337000
View original CVE JSON
{
"id": "CVE-2026-118791",
"sourceIdentifier": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"published": "2026-11-09T13:17:05.337",
"lastModified": "2026-11-09T13:17:05.337",
"vulnStatus": "Received",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The application implements software update functionality without adequate authenticity and integrity validation, allowing update packages to be accepted without sufficient cryptographic verification."
}
],
"affected": [
{
"source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"affectedData": [
{
"vendor": "CompuGroup Medical",
"product": "Wingesfar",
"defaultStatus": "unaffected",
"versions": [
{
"version": "0",
"lessThan": "10.2.1",
"versionType": "semver",
"status": "affected"
}
]
}
]
}
],
"metrics": {
"cvssMetricV40": [
{
"source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"type": "Secondary",
"cvssData": {
"version": "4.0",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "UNREPORTED",
"confidentialityRequirement": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"availabilityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED"
}
}
]
},
"weaknesses": [
{
"source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-494"
}
]
}
],
"references": [
{
"url": "https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical",
"source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158"
},
{
"url": "https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html",
"source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158"
}
]
}