CVE-2026-13208
Full vulnerability record from the local CVENow database.
Description
A flaw was found in KubeVirt's virt-handler domain notify server. The gRPC handlers for HandleDomainEvent and HandleK8SEvent derive the VMI identity (namespace/name) solely from the request body without validating it against the connection's origin. Each virt-launcher pod connects through a per-VMI pipe socket, but no identity tag is propagated from the pipe path to the server handlers. This allows a compromised virt-launcher process to send forged domain lifecycle events for any other VMI scheduled on the same node, causing virt-handler to erroneously update that VMI's state and disrupt its lifecycle management.
Severity
MEDIUM
CVSS score
6.5
(v3.1)
Vulnerability status
Analyzed
Source identifier
Published
2026-06-24 21:16:52.547000
Last modified
2026-10-25 22:10:00.150000
View original CVE JSON
{
"id": "CVE-2026-13208",
"sourceIdentifier": "[email protected]",
"published": "2026-06-24T21:16:52.547",
"lastModified": "2026-10-25T22:10:00.150",
"vulnStatus": "Analyzed",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A flaw was found in KubeVirt's virt-handler domain notify server. The gRPC handlers for HandleDomainEvent and HandleK8SEvent derive the VMI identity (namespace/name) solely from the request body without validating it against the connection's origin. Each virt-launcher pod connects through a per-VMI pipe socket, but no identity tag is propagated from the pipe path to the server handlers. This allows a compromised virt-launcher process to send forged domain lifecycle events for any other VMI scheduled on the same node, causing virt-handler to erroneously update that VMI's state and disrupt its lifecycle management."
},
{
"lang": "es",
"value": "Se encontró una falla en el servidor de notificación de dominio virt-handler de KubeVirt. Los gestores gRPC para HandleDomainEvent y HandleK8SEvent derivan la identidad de la VMI (namespace/name) únicamente del cuerpo de la solicitud sin validarla contra el origen de la conexión. Cada pod virt-launcher se conecta a través de un socket de tubería por VMI, pero no se propaga ninguna etiqueta de identidad desde la ruta de la tubería a los gestores del servidor. Esto permite a un proceso virt-launcher comprometido enviar eventos falsificados del ciclo de vida del dominio para cualquier otra VMI programada en el mismo nodo, haciendo que virt-handler actualice erróneamente el estado de esa VMI y perturbe su gestión del ciclo de vida."
}
],
"affected": [
{
"source": "[email protected]",
"affectedData": [
{
"vendor": "Red Hat",
"product": "Red Hat OpenShift Virtualization 4",
"defaultStatus": "affected",
"collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
"packageName": "container-native-virtualization/virt-handler",
"cpes": [
"cpe:/a:redhat:container_native_virtualization:4"
]
},
{
"vendor": "Red Hat",
"product": "Red Hat OpenShift Virtualization 4",
"defaultStatus": "affected",
"collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
"packageName": "container-native-virtualization/virt-handler-rhel9",
"cpes": [
"cpe:/a:redhat:container_native_virtualization:4"
]
}
]
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "[email protected]",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "CHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 2.0,
"impactScore": 4.0
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"timestamp": "2026-06-25T15:32:58.431125Z",
"id": "CVE-2026-13208",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
]
},
"weaknesses": [
{
"source": "[email protected]",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-287"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:kubevirt:kubevirt:-:*:*:*:*:kubernetes:*:*",
"matchCriteriaId": "06AF9668-6158-47F4-A755-0EE4D5F7F413"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:redhat:openshift_virtualization:*:*:*:*:*:*:*:*",
"versionStartIncluding": "4",
"versionEndIncluding": "4.22.0",
"matchCriteriaId": "5301905C-9B5C-479F-A69A-659C6CB3AA42"
}
]
}
]
}
],
"references": [
{
"url": "https://access.redhat.com/security/cve/CVE-2026-13208",
"source": "[email protected]",
"tags": [
"Mitigation",
"Vendor Advisory"
]
},
{
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=2492220",
"source": "[email protected]",
"tags": [
"Issue Tracking",
"Vendor Advisory"
]
}
]
}