← Back to CVE Explorer

CVE-2026-18772

Full vulnerability record from the local CVENow database.

Description

Improperly controlled sequential memory allocation vulnerability in Samsung Open Source rlottie allows Exponential Data Expansion.

Severity
MEDIUM
CVSS score
6.5 (v3.1)
Vulnerability status
Analyzed
Source identifier
Published
2026-08-04 10:19:32.923000
Last modified
2026-10-23 23:10:00.157000
View original CVE JSON
{
  "id": "CVE-2026-18772",
  "sourceIdentifier": "[email protected]",
  "published": "2026-08-04T10:19:32.923",
  "lastModified": "2026-10-23T23:10:00.157",
  "vulnStatus": "Analyzed",
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Improperly controlled sequential memory allocation vulnerability in Samsung Open Source rlottie allows Exponential Data Expansion."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de validación de entrada inadecuada en Samsung Open Source rlottie permite Cargas útiles de datos serializados sobredimensionadas."
    }
  ],
  "affected": [
    {
      "source": "[email protected]",
      "affectedData": [
        {
          "vendor": "Samsung Open Source",
          "product": "rlottie",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "f487eff2f8086b84ae1c7faa0418abec909e874b",
              "status": "unaffected"
            }
          ]
        }
      ]
    }
  ],
  "metrics": {
    "cvssMetricV31": [
      {
        "source": "[email protected]",
        "type": "Secondary",
        "cvssData": {
          "version": "3.1",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "attackVector": "NETWORK",
          "attackComplexity": "LOW",
          "privilegesRequired": "NONE",
          "userInteraction": "REQUIRED",
          "scope": "UNCHANGED",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "availabilityImpact": "HIGH"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "timestamp": "2026-08-04T13:16:08.111242Z",
          "id": "CVE-2026-18772",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "role": "CISA Coordinator",
          "version": "2.0.3"
        }
      }
    ]
  },
  "weaknesses": [
    {
      "source": "[email protected]",
      "type": "Secondary",
      "description": [
        {
          "lang": "en",
          "value": "CWE-1325"
        }
      ]
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "operator": "OR",
          "negate": false,
          "cpeMatch": [
            {
              "vulnerable": true,
              "criteria": "cpe:2.3:a:samsung:rlottie:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "839F9D6A-5E2B-4FDF-9F6F-CB9D3ED281F0"
            }
          ]
        }
      ]
    }
  ],
  "references": [
    {
      "url": "https://github.com/Samsung/rlottie/pull/596",
      "source": "[email protected]",
      "tags": [
        "Patch"
      ]
    }
  ]
}