← Back to CVE Explorer

CVE-2026-19657

Full vulnerability record from the local CVENow database.

Description

ScadaLTS 2.7.8.1 reflects user-supplied input into an HTML response without sanitization. An unauthenticated attacker who lures a victim into visiting a crafted URL can execute arbitrary JavaScript in the context of the victim's browser session.

Severity
MEDIUM
CVSS score
6.1 (v3.1)
Vulnerability status
Analyzed
Source identifier
Published
2026-08-12 20:17:43.060000
Last modified
2026-10-23 19:10:00.167000
View original CVE JSON
{
  "id": "CVE-2026-19657",
  "sourceIdentifier": "[email protected]",
  "published": "2026-08-12T20:17:43.060",
  "lastModified": "2026-10-23T19:10:00.167",
  "vulnStatus": "Analyzed",
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "ScadaLTS 2.7.8.1 reflects user-supplied input into an HTML response without sanitization. An unauthenticated attacker who lures a victim into visiting a crafted URL can execute arbitrary JavaScript in the context of the victim's browser session."
    },
    {
      "lang": "es",
      "value": "ScadaLTS 2.7.8.1 refleja la entrada proporcionada por el usuario en una respuesta HTML sin saneamiento. Un atacante no autenticado que atrae a una víctima para que visite una URL diseñada puede ejecutar JavaScript arbitrario en el contexto de la sesión del navegador de la víctima."
    }
  ],
  "affected": [
    {
      "source": "[email protected]",
      "affectedData": [
        {
          "vendor": "SCADA-LTS",
          "product": "ScadaLTS",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "2.7.8.1",
              "versionType": "semver",
              "status": "affected"
            }
          ]
        }
      ]
    }
  ],
  "metrics": {
    "cvssMetricV31": [
      {
        "source": "[email protected]",
        "type": "Secondary",
        "cvssData": {
          "version": "3.1",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
          "baseScore": 6.1,
          "baseSeverity": "MEDIUM",
          "attackVector": "NETWORK",
          "attackComplexity": "LOW",
          "privilegesRequired": "NONE",
          "userInteraction": "REQUIRED",
          "scope": "CHANGED",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "availabilityImpact": "NONE"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 2.7
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "timestamp": "2026-08-12T19:26:36.584772Z",
          "id": "CVE-2026-19657",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "role": "CISA Coordinator",
          "version": "2.0.3"
        }
      }
    ]
  },
  "weaknesses": [
    {
      "source": "[email protected]",
      "type": "Secondary",
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ]
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "operator": "OR",
          "negate": false,
          "cpeMatch": [
            {
              "vulnerable": true,
              "criteria": "cpe:2.3:a:scada-lts:scada-lts:2.7.8.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "E2A6612E-7A82-4F25-97FF-C8750A101595"
            }
          ]
        }
      ]
    }
  ],
  "references": [
    {
      "url": "https://www.tenable.com/security/research/tra-2026-55",
      "source": "[email protected]",
      "tags": [
        "Third Party Advisory"
      ]
    }
  ]
}