CVE-2026-19657
Full vulnerability record from the local CVENow database.
Description
ScadaLTS 2.7.8.1 reflects user-supplied input into an HTML response without sanitization. An unauthenticated attacker who lures a victim into visiting a crafted URL can execute arbitrary JavaScript in the context of the victim's browser session.
Severity
MEDIUM
CVSS score
6.1
(v3.1)
Vulnerability status
Analyzed
Source identifier
Published
2026-08-12 20:17:43.060000
Last modified
2026-10-23 19:10:00.167000
View original CVE JSON
{
"id": "CVE-2026-19657",
"sourceIdentifier": "[email protected]",
"published": "2026-08-12T20:17:43.060",
"lastModified": "2026-10-23T19:10:00.167",
"vulnStatus": "Analyzed",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "ScadaLTS 2.7.8.1 reflects user-supplied input into an HTML response without sanitization. An unauthenticated attacker who lures a victim into visiting a crafted URL can execute arbitrary JavaScript in the context of the victim's browser session."
},
{
"lang": "es",
"value": "ScadaLTS 2.7.8.1 refleja la entrada proporcionada por el usuario en una respuesta HTML sin saneamiento. Un atacante no autenticado que atrae a una víctima para que visite una URL diseñada puede ejecutar JavaScript arbitrario en el contexto de la sesión del navegador de la víctima."
}
],
"affected": [
{
"source": "[email protected]",
"affectedData": [
{
"vendor": "SCADA-LTS",
"product": "ScadaLTS",
"defaultStatus": "unaffected",
"versions": [
{
"version": "2.7.8.1",
"versionType": "semver",
"status": "affected"
}
]
}
]
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "[email protected]",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "CHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"timestamp": "2026-08-12T19:26:36.584772Z",
"id": "CVE-2026-19657",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
]
},
"weaknesses": [
{
"source": "[email protected]",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:scada-lts:scada-lts:2.7.8.1:*:*:*:*:*:*:*",
"matchCriteriaId": "E2A6612E-7A82-4F25-97FF-C8750A101595"
}
]
}
]
}
],
"references": [
{
"url": "https://www.tenable.com/security/research/tra-2026-55",
"source": "[email protected]",
"tags": [
"Third Party Advisory"
]
}
]
}