← Back to CVE Explorer

CVE-2026-2402

Full vulnerability record from the local CVENow database.

Description

CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on a sequence of requests to multiple endpoints.

Severity
MEDIUM
CVSS score
6.9 (v4.0)
Vulnerability status
Analyzed
Source identifier
Published
2026-04-14 16:16:38.767000
Last modified
2026-10-26 21:10:00.170000
View original CVE JSON
{
  "id": "CVE-2026-2402",
  "sourceIdentifier": "[email protected]",
  "published": "2026-04-14T16:16:38.767",
  "lastModified": "2026-10-26T21:10:00.170",
  "vulnStatus": "Analyzed",
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on a sequence of requests to multiple endpoints."
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad CWE-307 de Restricción Inadecuada de Intentos Excesivos de Autenticación que permitiría a un atacante obtener acceso a la cuenta de usuario al realizar un número arbitrario de intentos de autenticación con credenciales diferentes en una secuencia de solicitudes a múltiples puntos finales."
    }
  ],
  "affected": [
    {
      "source": "[email protected]",
      "affectedData": [
        {
          "vendor": "Schneider Electric",
          "product": "PowerChute™ Serial Shutdown",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "Versions v1.4 and prior",
              "status": "affected"
            }
          ]
        }
      ]
    }
  ],
  "metrics": {
    "cvssMetricV40": [
      {
        "source": "[email protected]",
        "type": "Secondary",
        "cvssData": {
          "version": "4.0",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "baseScore": 6.9,
          "baseSeverity": "MEDIUM",
          "attackVector": "NETWORK",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "NONE",
          "userInteraction": "NONE",
          "vulnConfidentialityImpact": "NONE",
          "vulnIntegrityImpact": "NONE",
          "vulnAvailabilityImpact": "LOW",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "subAvailabilityImpact": "NONE",
          "exploitMaturity": "NOT_DEFINED",
          "confidentialityRequirement": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "valueDensity": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "source": "[email protected]",
        "type": "Primary",
        "cvssData": {
          "version": "3.1",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
          "baseScore": 5.3,
          "baseSeverity": "MEDIUM",
          "attackVector": "NETWORK",
          "attackComplexity": "LOW",
          "privilegesRequired": "NONE",
          "userInteraction": "NONE",
          "scope": "UNCHANGED",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "availabilityImpact": "LOW"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 1.4
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "timestamp": "2026-04-14T16:26:07.842287Z",
          "id": "CVE-2026-2402",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "role": "CISA Coordinator",
          "version": "2.0.3"
        }
      }
    ]
  },
  "weaknesses": [
    {
      "source": "[email protected]",
      "type": "Secondary",
      "description": [
        {
          "lang": "en",
          "value": "CWE-307"
        }
      ]
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "operator": "OR",
          "negate": false,
          "cpeMatch": [
            {
              "vulnerable": true,
              "criteria": "cpe:2.3:a:schneider-electric:powerchute_serial_shutdown:*:*:*:*:*:*:*:*",
              "versionEndExcluding": "1.5",
              "matchCriteriaId": "503C9931-4346-4D3C-B6FF-02E663020A9D"
            }
          ]
        }
      ]
    }
  ],
  "references": [
    {
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-01.pdf",
      "source": "[email protected]",
      "tags": [
        "Vendor Advisory"
      ]
    }
  ]
}