Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special Elements used in an OS command ('OS command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to command execution.

Severity
MEDIUM
CVSS score
6.5 (v3.1)
Vulnerability status
Analyzed
Source identifier
Published
2026-07-03 13:17:02.320000
Last modified
2026-10-25 21:10:00.770000
View original CVE JSON
{
  "id": "CVE-2026-26355",
  "sourceIdentifier": "[email protected]",
  "published": "2026-07-03T13:17:02.320",
  "lastModified": "2026-10-25T21:10:00.770",
  "vulnStatus": "Analyzed",
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special Elements used in an OS command ('OS command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to command execution."
    },
    {
      "lang": "es",
      "value": "Dell PowerProtect Data Domain, versiones 7.7.1.0 hasta 8.7, versión de lanzamiento LTS2026 8.6.1.0 hasta 8.6.1.10, versión de lanzamiento LTS2025 8.3.1.0 hasta 8.3.1.30, versiones de lanzamiento LTS2024 7.13.1.0 hasta 7.13.1.70 contienen una vulnerabilidad de neutralización incorrecta de elementos especiales utilizados en un comando del sistema operativo (’inyección de comandos del SO’). Un atacante con altos privilegios y acceso remoto podría potencialmente explotar esta vulnerabilidad, lo que podría llevar a la ejecución de comandos."
    }
  ],
  "affected": [
    {
      "source": "[email protected]",
      "affectedData": [
        {
          "vendor": "Dell",
          "product": "PowerProtect Data Domain",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "lessThan": "8.8.0.0 or later",
              "versionType": "semver",
              "status": "affected"
            },
            {
              "version": "0",
              "lessThan": "8.6.1.20 or later",
              "versionType": "semver",
              "status": "affected"
            },
            {
              "version": "0",
              "lessThan": "8.3.1.40 or later",
              "versionType": "semver",
              "status": "affected"
            },
            {
              "version": "0",
              "lessThan": "7.13.1.80 or later",
              "versionType": "semver",
              "status": "affected"
            }
          ]
        }
      ]
    }
  ],
  "metrics": {
    "cvssMetricV31": [
      {
        "source": "[email protected]",
        "type": "Secondary",
        "cvssData": {
          "version": "3.1",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "attackVector": "NETWORK",
          "attackComplexity": "LOW",
          "privilegesRequired": "HIGH",
          "userInteraction": "NONE",
          "scope": "UNCHANGED",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "availabilityImpact": "HIGH"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 5.2
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "timestamp": "2026-07-06T00:00:00+00:00",
          "id": "CVE-2026-26355",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "role": "CISA Coordinator",
          "version": "2.0.3"
        }
      }
    ]
  },
  "weaknesses": [
    {
      "source": "[email protected]",
      "type": "Secondary",
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ]
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "operator": "OR",
          "negate": false,
          "cpeMatch": [
            {
              "vulnerable": true,
              "criteria": "cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*",
              "versionStartIncluding": "7.7.1.0",
              "versionEndExcluding": "7.13.1.80",
              "matchCriteriaId": "064F56BA-B974-4133-9DFA-B13D503766AC"
            },
            {
              "vulnerable": true,
              "criteria": "cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*",
              "versionStartIncluding": "8.3.1.0",
              "versionEndExcluding": "8.3.1.40",
              "matchCriteriaId": "C7291573-9C79-45AA-9675-18274FA52BAA"
            },
            {
              "vulnerable": true,
              "criteria": "cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*",
              "versionStartIncluding": "8.6.1.0",
              "versionEndExcluding": "8.6.1.20",
              "matchCriteriaId": "54CE0223-C1DD-448E-86DE-CF95EF6FBA48"
            }
          ]
        }
      ]
    }
  ],
  "references": [
    {
      "url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities",
      "source": "[email protected]",
      "tags": [
        "Vendor Advisory"
      ]
    }
  ]
}