← Back to CVE Explorer

CVE-2026-28322

Full vulnerability record from the local CVENow database.

Description

SolarWinds Database Performance Analyzer was found to be affected by a stored cross-site scripting vulnerability, which when exploited, can lead to unintended script execution.

Severity
MEDIUM
CVSS score
5.6 (v3.1)
Vulnerability status
Awaiting Analysis
Source identifier
Published
2026-06-30 23:17:26.993000
Last modified
2026-10-25 17:10:00.197000
View original CVE JSON
{
  "id": "CVE-2026-28322",
  "sourceIdentifier": "[email protected]",
  "published": "2026-06-30T23:17:26.993",
  "lastModified": "2026-10-25T17:10:00.197",
  "vulnStatus": "Awaiting Analysis",
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "SolarWinds Database Performance Analyzer was found to be affected by a stored cross-site scripting vulnerability, which when exploited, can lead to unintended script execution."
    },
    {
      "lang": "es",
      "value": "SolarWinds Analizador de Rendimiento de Base de Datos se encontró que estaba afectado por una vulnerabilidad de cross-site scripting almacenado, la cual, al ser explotada, puede llevar a la ejecución de scripts no deseados."
    }
  ],
  "affected": [
    {
      "source": "[email protected]",
      "affectedData": [
        {
          "vendor": "SolarWinds",
          "product": "Database Performance Analyzer",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "2026.1 and below",
              "status": "affected"
            }
          ]
        }
      ]
    }
  ],
  "metrics": {
    "cvssMetricV31": [
      {
        "source": "[email protected]",
        "type": "Secondary",
        "cvssData": {
          "version": "3.1",
          "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:N",
          "baseScore": 5.6,
          "baseSeverity": "MEDIUM",
          "attackVector": "ADJACENT_NETWORK",
          "attackComplexity": "HIGH",
          "privilegesRequired": "HIGH",
          "userInteraction": "REQUIRED",
          "scope": "UNCHANGED",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "availabilityImpact": "NONE"
        },
        "exploitabilityScore": 0.4,
        "impactScore": 5.2
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "timestamp": "2026-07-01T00:00:00+00:00",
          "id": "CVE-2026-28322",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "role": "CISA Coordinator",
          "version": "2.0.3"
        }
      }
    ]
  },
  "weaknesses": [
    {
      "source": "[email protected]",
      "type": "Secondary",
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ]
    }
  ],
  "references": [
    {
      "url": "https://documentation.solarwinds.com/en/success_center/dpa/content/release_notes/dpa_2026-2_release_notes.htm",
      "source": "[email protected]"
    },
    {
      "url": "https://support.solarwinds.com/SuccessCenter/s/article/DPA-Secure-Configuration-Guide-Best-Practices-and-Recommendations?language=en_US",
      "source": "[email protected]"
    },
    {
      "url": "https://www.solarwinds.com/trust-center/security-advisories/cve-2026-28322",
      "source": "[email protected]"
    }
  ]
}