CVE-2026-34021
Full vulnerability record from the local CVENow database.
Description
The Wertheim SafeController 5400, Controller 5400 - AssemblyVersion 6.11.8130.22320, uses RS-485 communication between the server and the microcontroller without cryptographic protection. An attacker with access to the communication path between the server and the microcontroller can sniff RS-485 messages and replay previously observed messages. This can be used, for example, to spoof a "quit alarm" message and continuously deactivate the safe alarm.
Severity
HIGH
CVSS score
8.6
(v4.0)
Vulnerability status
Deferred
Source identifier
551230f0-3615-47bd-b7cc-93e92e730bbf
Published
2026-06-15 12:16:24.230000
Last modified
2026-10-25 23:10:00.167000
View original CVE JSON
{
"id": "CVE-2026-34021",
"sourceIdentifier": "551230f0-3615-47bd-b7cc-93e92e730bbf",
"published": "2026-06-15T12:16:24.230",
"lastModified": "2026-10-25T23:10:00.167",
"vulnStatus": "Deferred",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The Wertheim SafeController 5400, Controller 5400 - AssemblyVersion 6.11.8130.22320, uses RS-485 communication between the server and the microcontroller without cryptographic protection. An attacker with access to the communication path between the server and the microcontroller can sniff RS-485 messages and replay previously observed messages. This can be used, for example, to spoof a \"quit alarm\" message and continuously deactivate the safe alarm."
},
{
"lang": "es",
"value": "El Wertheim SafeController 5400, Controller 5400 - AssemblyVersion 6.11.8130.22320, utiliza comunicación RS-485 entre el servidor y el microcontrolador sin protección criptográfica. Un atacante con acceso a la ruta de comunicación entre el servidor y el microcontrolador puede interceptar mensajes RS-485 y reproducir mensajes observados previamente. Esto puede utilizarse, por ejemplo, para suplantar un mensaje de ’alarma desactivada’ y desactivar continuamente la alarma de la caja fuerte."
}
],
"affected": [
{
"source": "551230f0-3615-47bd-b7cc-93e92e730bbf",
"affectedData": [
{
"vendor": "Wertheim GmbH",
"product": "Wertheim SafeController 5400 Hardware for VAULT ROOMS (Safe Deposit Locker System - Microcontroller)",
"defaultStatus": "unknown",
"versions": [
{
"version": "Wertheim SafeController 5400, Controller 5400 - AssemblyVersion 6.11.8130.22320",
"status": "affected"
}
]
}
]
}
],
"metrics": {
"cvssMetricV40": [
{
"source": "551230f0-3615-47bd-b7cc-93e92e730bbf",
"type": "Secondary",
"cvssData": {
"version": "4.0",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"attackVector": "ADJACENT",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"confidentialityRequirement": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"availabilityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED"
}
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"timestamp": "2026-06-15T13:10:35.328416Z",
"id": "CVE-2026-34021",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
]
},
"weaknesses": [
{
"source": "551230f0-3615-47bd-b7cc-93e92e730bbf",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-294"
}
]
}
],
"references": [
{
"url": "https://r.sec-consult.com/wertdev",
"source": "551230f0-3615-47bd-b7cc-93e92e730bbf"
},
{
"url": "https://wertheim-safes.com/safe-deposit-boxes/",
"source": "551230f0-3615-47bd-b7cc-93e92e730bbf"
},
{
"url": "https://sec-consult.com/vulnerability-lab/advisory/multiple-vulnerabilities-in-wertheim-safecontroller-hardware-for-vault-rooms-safe-deposit-locker-system-microcontroller/",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
]
}