CVE-2026-39815
Full vulnerability record from the local CVENow database.
Description
A improper neutralization of special elements used in an sql command ('sql injection') vulnerability in Fortinet FortiDDoS-F 7.2.1 through 7.2.2 may allow attacker to execute unauthorized code or commands via sending crafted HTTP requests
Severity
HIGH
CVSS score
8.8
(v3.1)
Vulnerability status
Analyzed
Source identifier
Published
2026-04-14 16:16:46.383000
Last modified
2026-10-26 21:10:00.170000
View original CVE JSON
{
"id": "CVE-2026-39815",
"sourceIdentifier": "[email protected]",
"published": "2026-04-14T16:16:46.383",
"lastModified": "2026-10-26T21:10:00.170",
"vulnStatus": "Analyzed",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A improper neutralization of special elements used in an sql command ('sql injection') vulnerability in Fortinet FortiDDoS-F 7.2.1 through 7.2.2 may allow attacker to execute unauthorized code or commands via sending crafted HTTP requests"
},
{
"lang": "es",
"value": "Una vulnerabilidad de neutralización inadecuada de elementos especiales utilizados en un comando SQL (’inyección SQL’) en Fortinet FortiDDoS-F 7.2.1 a 7.2.2 puede permitir al atacante ejecutar código o comandos no autorizados mediante el envío de solicitudes HTTP manipuladas."
}
],
"affected": [
{
"source": "[email protected]",
"affectedData": [
{
"vendor": "Fortinet",
"product": "FortiDDoS-F",
"defaultStatus": "unaffected",
"cpes": [
"cpe:2.3:o:fortinet:fortiddos-f:7.2.2:*:*:*:*:*:*:*",
"cpe:2.3:o:fortinet:fortiddos-f:7.2.1:*:*:*:*:*:*:*"
],
"versions": [
{
"version": "7.2.1",
"lessThanOrEqual": "7.2.2",
"versionType": "semver",
"status": "affected"
}
]
}
]
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "[email protected]",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"timestamp": "2026-04-14T16:22:55.316897Z",
"id": "CVE-2026-39815",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
]
},
"weaknesses": [
{
"source": "[email protected]",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-89"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:fortinet:fortiddos-f:*:*:*:*:*:*:*:*",
"versionStartIncluding": "7.2.1",
"versionEndExcluding": "7.2.3",
"matchCriteriaId": "D689EF4D-14F7-4D42-8814-2A44EE85C304"
}
]
}
]
}
],
"references": [
{
"url": "https://fortiguard.fortinet.com/psirt/FG-IR-26-119",
"source": "[email protected]",
"tags": [
"Vendor Advisory"
]
}
]
}