← Back to CVE Explorer

CVE-2026-44268

Full vulnerability record from the local CVENow database.

Description

Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an incorrect permission Assignment for critical resource vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to unauthorized access.

Severity
MEDIUM
CVSS score
4.4 (v3.1)
Vulnerability status
Analyzed
Source identifier
Published
2026-07-03 13:17:15.750000
Last modified
2026-10-25 21:10:00.770000
View original CVE JSON
{
  "id": "CVE-2026-44268",
  "sourceIdentifier": "[email protected]",
  "published": "2026-07-03T13:17:15.750",
  "lastModified": "2026-10-25T21:10:00.770",
  "vulnStatus": "Analyzed",
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an incorrect permission Assignment for critical resource vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to unauthorized access."
    },
    {
      "lang": "es",
      "value": "Dell PowerProtect Data Domain, versiones 7.7.1.0 hasta 8.6, versión de lanzamiento LTS2026 8.6.1.0 hasta 8.6.1.10, versión de lanzamiento LTS2025 8.3.1.0 hasta 8.3.1.30, versiones de lanzamiento LTS2024 7.13.1.0 hasta 7.13.1.70 contienen una vulnerabilidad de asignación de permisos incorrecta para un recurso crítico. Un atacante con altos privilegios y acceso local podría potencialmente explotar esta vulnerabilidad, lo que llevaría a un acceso no autorizado."
    }
  ],
  "affected": [
    {
      "source": "[email protected]",
      "affectedData": [
        {
          "vendor": "Dell",
          "product": "PowerProtect Data Domain",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "lessThan": "8.7.0.0 or later",
              "versionType": "semver",
              "status": "affected"
            },
            {
              "version": "0",
              "lessThan": "8.6.1.20 or later",
              "versionType": "semver",
              "status": "affected"
            },
            {
              "version": "0",
              "lessThan": "8.3.1.40 or later",
              "versionType": "semver",
              "status": "affected"
            },
            {
              "version": "0",
              "lessThan": "7.13.1.80 or later",
              "versionType": "semver",
              "status": "affected"
            }
          ]
        }
      ]
    }
  ],
  "metrics": {
    "cvssMetricV31": [
      {
        "source": "[email protected]",
        "type": "Secondary",
        "cvssData": {
          "version": "3.1",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
          "baseScore": 4.4,
          "baseSeverity": "MEDIUM",
          "attackVector": "LOCAL",
          "attackComplexity": "LOW",
          "privilegesRequired": "HIGH",
          "userInteraction": "NONE",
          "scope": "UNCHANGED",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "availabilityImpact": "NONE"
        },
        "exploitabilityScore": 0.8,
        "impactScore": 3.6
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "timestamp": "2026-07-06T14:21:24.648770Z",
          "id": "CVE-2026-44268",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "role": "CISA Coordinator",
          "version": "2.0.3"
        }
      }
    ]
  },
  "weaknesses": [
    {
      "source": "[email protected]",
      "type": "Secondary",
      "description": [
        {
          "lang": "en",
          "value": "CWE-732"
        }
      ]
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "operator": "OR",
          "negate": false,
          "cpeMatch": [
            {
              "vulnerable": true,
              "criteria": "cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*",
              "versionStartIncluding": "7.7.1.0",
              "versionEndIncluding": "7.13.1.70",
              "matchCriteriaId": "D81B827B-47D1-4856-ABEE-7FDB8599AD42"
            },
            {
              "vulnerable": true,
              "criteria": "cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*",
              "versionStartIncluding": "8.0.0.0",
              "versionEndIncluding": "8.3.1.30",
              "matchCriteriaId": "3A1E837C-2175-494D-8C20-EB25AE30F07F"
            },
            {
              "vulnerable": true,
              "criteria": "cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*",
              "versionStartIncluding": "8.4.0.0",
              "versionEndIncluding": "8.6.1.10",
              "matchCriteriaId": "1717B5B3-E190-4BE6-AAFC-CE0924D8497E"
            }
          ]
        }
      ]
    }
  ],
  "references": [
    {
      "url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities",
      "source": "[email protected]",
      "tags": [
        "Vendor Advisory"
      ]
    }
  ]
}