A vulnerability in the command line interface of ECOS devices could allow a highly privileged, authenticated remote attacker to perform command injection on certain CLI commands. Successful exploitation could allow an attacker to execute arbitrary commands on the underlying operating system.

Severity
HIGH
CVSS score
7.2 (v3.1)
Vulnerability status
Awaiting Analysis
Source identifier
Published
2026-07-21 21:16:49.750000
Last modified
2026-10-24 19:10:00.127000
View original CVE JSON
{
  "id": "CVE-2026-44879",
  "sourceIdentifier": "[email protected]",
  "published": "2026-07-21T21:16:49.750",
  "lastModified": "2026-10-24T19:10:00.127",
  "vulnStatus": "Awaiting Analysis",
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability in the command line interface of ECOS devices could allow a highly privileged, authenticated remote attacker to perform command injection on certain CLI commands. Successful exploitation could allow an attacker to execute arbitrary commands on the underlying operating system."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad en la interfaz de línea de comandos de los dispositivos ECOS podría permitir a un atacante remoto autenticado y altamente privilegiado realizar inyección de comandos en ciertos comandos de la CLI. La explotación exitosa podría permitir a un atacante ejecutar comandos arbitrarios en el sistema operativo subyacente."
    }
  ],
  "affected": [
    {
      "source": "[email protected]",
      "affectedData": [
        {
          "vendor": "Hewlett Packard Enterprise (HPE)",
          "product": "EdgeConnect SD-WAN Gateway (ECOS)",
          "defaultStatus": "affected",
          "versions": [
            {
              "version": "9.4.0.0",
              "lessThanOrEqual": "9.4.4.0",
              "versionType": "semver",
              "status": "affected"
            },
            {
              "version": "9.5.0.0",
              "lessThanOrEqual": "9.5.4.0",
              "versionType": "semver",
              "status": "affected"
            }
          ]
        }
      ]
    }
  ],
  "metrics": {
    "cvssMetricV31": [
      {
        "source": "[email protected]",
        "type": "Secondary",
        "cvssData": {
          "version": "3.1",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "baseScore": 7.2,
          "baseSeverity": "HIGH",
          "attackVector": "NETWORK",
          "attackComplexity": "LOW",
          "privilegesRequired": "HIGH",
          "userInteraction": "NONE",
          "scope": "UNCHANGED",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "availabilityImpact": "HIGH"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 5.9
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "timestamp": "2026-07-23T13:31:05.643166Z",
          "id": "CVE-2026-44879",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "role": "CISA Coordinator",
          "version": "2.0.3"
        }
      }
    ]
  },
  "weaknesses": [
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary",
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ]
    }
  ],
  "references": [
    {
      "url": "https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw05013en_us&docLocale=en_US",
      "source": "[email protected]"
    }
  ]
}