CVE-2026-46737
Full vulnerability record from the local CVENow database.
Description
Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Improper Input Validation vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Remote execution.
Severity
HIGH
CVSS score
7.2
(v3.1)
Vulnerability status
Analyzed
Source identifier
Published
2026-07-22 16:17:24.093000
Last modified
2026-10-24 13:10:00.147000
View original CVE JSON
{
"id": "CVE-2026-46737",
"sourceIdentifier": "[email protected]",
"published": "2026-07-22T16:17:24.093",
"lastModified": "2026-10-24T13:10:00.147",
"vulnStatus": "Analyzed",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Improper Input Validation vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Remote execution."
},
{
"lang": "es",
"value": "Dell PowerProtect Data Manager, versiones anteriores a 20.2.0.0, contiene una vulnerabilidad de validación de entrada incorrecta en la API REST. Un atacante con altos privilegios y acceso remoto podría potencialmente explotar esta vulnerabilidad, lo que lleva a la ejecución remota."
}
],
"affected": [
{
"source": "[email protected]",
"affectedData": [
{
"vendor": "Dell",
"product": "PowerProtect Data Manager",
"defaultStatus": "unaffected",
"versions": [
{
"version": "0",
"lessThan": "20.2.0.0 or later",
"versionType": "semver",
"status": "affected"
}
]
}
]
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "[email protected]",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:L/A:H",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 1.2,
"impactScore": 5.5
},
{
"source": "[email protected]",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"timestamp": "2026-07-24T03:56:09.645163Z",
"id": "CVE-2026-46737",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
]
},
"weaknesses": [
{
"source": "[email protected]",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-20"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:dell:powerprotect_data_manager:*:*:*:*:*:*:*:*",
"versionEndExcluding": "20.2",
"matchCriteriaId": "FB53FFAB-07F4-4CE5-A572-55DC62C64641"
}
]
}
]
}
],
"references": [
{
"url": "https://www.dell.com/support/kbdoc/en-us/000488847/dsa-2026-287-security-update-dell-powerprotect-data-manager-for-multiple-security-vulnerabilities",
"source": "[email protected]",
"tags": [
"Vendor Advisory"
]
}
]
}