CVE-2026-54376
Full vulnerability record from the local CVENow database.
Description
VitaFit Android application (com.vt.vitafit) before 2.8.1.0 contains an insecure custom URI scheme vulnerability that allows a malicious application to intercept Fitbit login tokens by registering the same callback scheme (vitafit://vtio.cn). Attackers can capture the 30-day Fitbit authorization token with weight scope delivered in the callback URL to read, create, and delete the victim's weight and body-fat records via the Fitbit Body API.
Severity
HIGH
CVSS score
8.2
(v4.0)
Vulnerability status
Received
Source identifier
Published
2026-11-04 22:18:05.407000
Last modified
2026-11-04 22:18:05.407000
View original CVE JSON
{
"id": "CVE-2026-54376",
"sourceIdentifier": "[email protected]",
"published": "2026-11-04T22:18:05.407",
"lastModified": "2026-11-04T22:18:05.407",
"vulnStatus": "Received",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "VitaFit Android application (com.vt.vitafit) before 2.8.1.0 contains an insecure custom URI scheme vulnerability that allows a malicious application to intercept Fitbit login tokens by registering the same callback scheme (vitafit://vtio.cn). Attackers can capture the 30-day Fitbit authorization token with weight scope delivered in the callback URL to read, create, and delete the victim's weight and body-fat records via the Fitbit Body API."
}
],
"affected": [
{
"source": "[email protected]",
"affectedData": [
{
"vendor": "Shenzhen Shine Industrial Co., Ltd.",
"product": "VitaFit",
"defaultStatus": "unaffected",
"versions": [
{
"version": "0",
"lessThan": "2.8.1.0",
"versionType": "custom",
"status": "affected"
}
]
}
]
}
],
"metrics": {
"cvssMetricV40": [
{
"source": "[email protected]",
"type": "Secondary",
"cvssData": {
"version": "4.0",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:N/VA:N/SC:H/SI:H/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"userInteraction": "ACTIVE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"confidentialityRequirement": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"availabilityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED"
}
}
],
"cvssMetricV31": [
{
"source": "[email protected]",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:N",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "CHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 1.8,
"impactScore": 5.8
}
]
},
"weaknesses": [
{
"source": "[email protected]",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-926"
}
]
}
],
"references": [
{
"url": "https://github.com/je-lv/vitafit-security-research",
"source": "[email protected]"
},
{
"url": "https://play.google.com/store/apps/details?id=com.vt.vitafit",
"source": "[email protected]"
},
{
"url": "https://www.vulncheck.com/advisories/vitafit-android-custom-uri-scheme-token-hijacking",
"source": "[email protected]"
}
]
}