CVE-2026-62799
Full vulnerability record from the local CVENow database.
Description
Heap-based buffer overflow in Windows SMB Client allows an authorized attacker to elevate privileges locally.
Severity
HIGH
CVSS score
7.8
(v3.1)
Vulnerability status
Analyzed
Source identifier
Published
2026-08-11 17:18:34.180000
Last modified
2026-10-24 16:10:00.153000
View original CVE JSON
{
"id": "CVE-2026-62799",
"sourceIdentifier": "[email protected]",
"published": "2026-08-11T17:18:34.180",
"lastModified": "2026-10-24T16:10:00.153",
"vulnStatus": "Analyzed",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Heap-based buffer overflow in Windows SMB Client allows an authorized attacker to elevate privileges locally."
},
{
"lang": "es",
"value": "Desbordamiento de búfer basado en montículo en el cliente SMB de Windows permite a un atacante autorizado elevar privilegios localmente."
}
],
"affected": [
{
"source": "[email protected]",
"affectedData": [
{
"vendor": "Microsoft",
"product": "Windows 11 version 26H1",
"platforms": [
"ARM64-based Systems",
"x64-based Systems"
],
"versions": [
{
"version": "10.0.28000.0",
"lessThan": "10.0.28000.2704",
"versionType": "custom",
"status": "affected"
}
]
}
]
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "[email protected]",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"timestamp": "2026-08-12T03:56:13.382390Z",
"id": "CVE-2026-62799",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
]
},
"weaknesses": [
{
"source": "[email protected]",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-122"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:microsoft:windows_11_26h1:*:*:*:*:*:*:arm64:*",
"versionEndExcluding": "10.0.28000.2704",
"matchCriteriaId": "BE88CAB4-881C-4300-AA9F-0E3F59371786"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:o:microsoft:windows_11_26h1:*:*:*:*:*:*:x64:*",
"versionEndExcluding": "10.0.28000.2704",
"matchCriteriaId": "DBF52600-4F74-4C60-8792-0BB6CA65823A"
}
]
}
]
}
],
"references": [
{
"url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2026-62799",
"source": "[email protected]",
"tags": [
"Patch",
"Vendor Advisory"
]
}
]
}