← Back to CVE Explorer

CVE-2026-6865

Full vulnerability record from the local CVENow database.

Description

CWE-22: Improper Limitation of a Pathname to a Restricted Directory (“Path Traversal”) vulnerability that could cause unauthorized access to sensitive files when user-supplied input is improperly handled during server-side file path processing.

Severity
HIGH
CVSS score
7.1 (v4.0)
Vulnerability status
Awaiting Analysis
Source identifier
Published
2026-05-12 14:17:10.567000
Last modified
2026-10-26 18:10:00.173000
View original CVE JSON
{
  "id": "CVE-2026-6865",
  "sourceIdentifier": "[email protected]",
  "published": "2026-05-12T14:17:10.567",
  "lastModified": "2026-10-26T18:10:00.173",
  "vulnStatus": "Awaiting Analysis",
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (“Path Traversal”) vulnerability that could cause unauthorized access to sensitive files when user-supplied input is improperly handled during server-side file path processing."
    },
    {
      "lang": "es",
      "value": "CWE-22: Limitación inadecuada de un nombre de ruta a un directorio restringido (’Salto de ruta’) vulnerabilidad que podría causar acceso no autorizado a archivos sensibles cuando la entrada proporcionada por el usuario se maneja de forma inadecuada durante el procesamiento de rutas de archivo del lado del servidor."
    }
  ],
  "affected": [
    {
      "source": "[email protected]",
      "affectedData": [
        {
          "vendor": "Schneider Electric",
          "product": "EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "Versions 11.06.31 and prior",
              "status": "affected"
            }
          ]
        },
        {
          "vendor": "Schneider Electric",
          "product": "Saitel DP Remote Terminal Unit & Controller",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "Versions 11.06.36 and prior",
              "status": "affected"
            }
          ]
        }
      ]
    }
  ],
  "metrics": {
    "cvssMetricV40": [
      {
        "source": "[email protected]",
        "type": "Secondary",
        "cvssData": {
          "version": "4.0",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "baseScore": 7.1,
          "baseSeverity": "HIGH",
          "attackVector": "NETWORK",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "LOW",
          "userInteraction": "NONE",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "LOW",
          "vulnAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "subAvailabilityImpact": "NONE",
          "exploitMaturity": "NOT_DEFINED",
          "confidentialityRequirement": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "valueDensity": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED"
        }
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "timestamp": "2026-05-12T14:35:42.694103Z",
          "id": "CVE-2026-6865",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "role": "CISA Coordinator",
          "version": "2.0.3"
        }
      }
    ]
  },
  "weaknesses": [
    {
      "source": "[email protected]",
      "type": "Secondary",
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ]
    }
  ],
  "references": [
    {
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-132-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-132-03.pdf",
      "source": "[email protected]"
    }
  ]
}