CVE-2026-6865
Full vulnerability record from the local CVENow database.
Description
CWE-22: Improper Limitation of a Pathname to a Restricted Directory (“Path Traversal”) vulnerability that could cause unauthorized access to sensitive files when user-supplied input is improperly handled during server-side file path processing.
Severity
HIGH
CVSS score
7.1
(v4.0)
Vulnerability status
Awaiting Analysis
Source identifier
Published
2026-05-12 14:17:10.567000
Last modified
2026-10-26 18:10:00.173000
View original CVE JSON
{
"id": "CVE-2026-6865",
"sourceIdentifier": "[email protected]",
"published": "2026-05-12T14:17:10.567",
"lastModified": "2026-10-26T18:10:00.173",
"vulnStatus": "Awaiting Analysis",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (“Path Traversal”) vulnerability that could cause unauthorized access to sensitive files when user-supplied input is improperly handled during server-side file path processing."
},
{
"lang": "es",
"value": "CWE-22: Limitación inadecuada de un nombre de ruta a un directorio restringido (’Salto de ruta’) vulnerabilidad que podría causar acceso no autorizado a archivos sensibles cuando la entrada proporcionada por el usuario se maneja de forma inadecuada durante el procesamiento de rutas de archivo del lado del servidor."
}
],
"affected": [
{
"source": "[email protected]",
"affectedData": [
{
"vendor": "Schneider Electric",
"product": "EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller",
"defaultStatus": "unaffected",
"versions": [
{
"version": "Versions 11.06.31 and prior",
"status": "affected"
}
]
},
{
"vendor": "Schneider Electric",
"product": "Saitel DP Remote Terminal Unit & Controller",
"defaultStatus": "unaffected",
"versions": [
{
"version": "Versions 11.06.36 and prior",
"status": "affected"
}
]
}
]
}
],
"metrics": {
"cvssMetricV40": [
{
"source": "[email protected]",
"type": "Secondary",
"cvssData": {
"version": "4.0",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "LOW",
"vulnAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"confidentialityRequirement": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"availabilityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED"
}
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"timestamp": "2026-05-12T14:35:42.694103Z",
"id": "CVE-2026-6865",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
]
},
"weaknesses": [
{
"source": "[email protected]",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-22"
}
]
}
],
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-132-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-132-03.pdf",
"source": "[email protected]"
}
]
}