← Back to CVE Explorer

CVE-2026-6888

Full vulnerability record from the local CVENow database.

Description

Successful exploitation of the SQL injection vulnerability could allow a remote authenticated attacker to execute arbitrary commands via a specific interface, potentially enabling the attacker to access, modify, or delete sensitive information within the database.

Severity
HIGH
CVSS score
7.2 (v3.1)
Vulnerability status
Awaiting Analysis
Source identifier
5f57b9bf-260d-4433-bf07-b6a79e9bb7d4
Published
2026-05-13 04:17:41.093000
Last modified
2026-10-26 18:10:00.173000
View original CVE JSON
{
  "id": "CVE-2026-6888",
  "sourceIdentifier": "5f57b9bf-260d-4433-bf07-b6a79e9bb7d4",
  "published": "2026-05-13T04:17:41.093",
  "lastModified": "2026-10-26T18:10:00.173",
  "vulnStatus": "Awaiting Analysis",
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Successful exploitation of the SQL injection vulnerability could allow a remote authenticated attacker to\nexecute arbitrary commands via a specific interface,\npotentially enabling the attacker to access, modify, or delete sensitive\ninformation within the database."
    },
    {
      "lang": "es",
      "value": "Explotación exitosa de la vulnerabilidad de inyección SQL podría permitir a un atacante remoto autenticado ejecutar comandos arbitrarios a través de una interfaz específica, lo que podría permitir al atacante acceder, modificar o eliminar información sensible dentro de la base de datos."
    }
  ],
  "affected": [
    {
      "source": "5f57b9bf-260d-4433-bf07-b6a79e9bb7d4",
      "affectedData": [
        {
          "vendor": "Advantech",
          "product": "SaaS Composer",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "prior to version 3.4.17",
              "status": "affected"
            }
          ]
        },
        {
          "vendor": "Advantech",
          "product": "IoTSuite Growth Linux docker",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "prior to version 2.2.0",
              "status": "affected"
            }
          ]
        },
        {
          "vendor": "Advantech",
          "product": "IoTSuite Starter Linux docker",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "prior to version 2.2.0",
              "status": "affected"
            }
          ]
        },
        {
          "vendor": "Advantech",
          "product": "IoT Edge Linux docker",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "prior to version 2.2.0",
              "status": "affected"
            }
          ]
        },
        {
          "vendor": "Advantech",
          "product": "IoT Edge Windows",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "prior to version 2.2.0",
              "status": "affected"
            }
          ]
        },
        {
          "vendor": "Advantech",
          "product": "WebAccess/SCADA",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "prior to version 9.2.3",
              "status": "affected"
            }
          ]
        },
        {
          "vendor": "Advantech",
          "product": "WebAccess SaaS-Composer",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "prior to version 3.4.17.1",
              "status": "affected"
            }
          ]
        },
        {
          "vendor": "Advantech",
          "product": "ECOWatch SaaS-Composer",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "prior to version 3.4.17",
              "status": "affected"
            }
          ]
        }
      ]
    }
  ],
  "metrics": {
    "cvssMetricV31": [
      {
        "source": "5f57b9bf-260d-4433-bf07-b6a79e9bb7d4",
        "type": "Secondary",
        "cvssData": {
          "version": "3.1",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "baseScore": 7.2,
          "baseSeverity": "HIGH",
          "attackVector": "NETWORK",
          "attackComplexity": "LOW",
          "privilegesRequired": "HIGH",
          "userInteraction": "NONE",
          "scope": "UNCHANGED",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "availabilityImpact": "HIGH"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 5.9
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "timestamp": "2026-05-13T14:35:40.247452Z",
          "id": "CVE-2026-6888",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "role": "CISA Coordinator",
          "version": "2.0.3"
        }
      }
    ]
  },
  "weaknesses": [
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary",
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ]
    }
  ],
  "references": [
    {
      "url": "https://www.csa.gov.sg/alerts-and-advisories/alerts/al-2026-050/",
      "source": "5f57b9bf-260d-4433-bf07-b6a79e9bb7d4"
    }
  ]
}