CVE-2026-78403
Full vulnerability record from the local CVENow database.
Description
Stack-based buffer overflow and missing authorization vulnerability in Thales Sentinel Keys Server on Windows allows Overflow Buffers. Sentinel Keys Server does not check the length of the first field in the HTTP request. An attacker may craft an HTTP request and send it to Sentinel Keys Server. It may lead to remote code execution as NT AUTHORITY\SYSTEM. This issue affects Sentinel Keys Server: versions lower than 1.3.8.0.
Severity
CRITICAL
CVSS score
9.3
(v4.0)
Vulnerability status
Received
Source identifier
Published
2026-10-30 20:17:17.843000
Last modified
2026-10-30 20:17:17.843000
View original CVE JSON
{
"id": "CVE-2026-78403",
"sourceIdentifier": "[email protected]",
"published": "2026-10-30T20:17:17.843",
"lastModified": "2026-10-30T20:17:17.843",
"vulnStatus": "Received",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Stack-based buffer overflow and missing\nauthorization vulnerability in Thales Sentinel Keys Server on Windows allows\nOverflow Buffers. Sentinel Keys Server does not check the length of the first\nfield in the HTTP request. An attacker may craft an HTTP request and send it to\nSentinel Keys Server. It may lead to remote code execution as NT\nAUTHORITY\\SYSTEM.\n\n\n\n\n\nThis issue affects Sentinel Keys Server:\nversions lower than 1.3.8.0."
}
],
"affected": [
{
"source": "[email protected]",
"affectedData": [
{
"vendor": "Thalesgroup",
"product": "Sentinel Keys Server",
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"versions": [
{
"version": "0",
"lessThan": "1.3.8.0",
"versionType": "custom",
"status": "affected"
}
]
}
]
}
],
"metrics": {
"cvssMetricV40": [
{
"source": "[email protected]",
"type": "Secondary",
"cvssData": {
"version": "4.0",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"confidentialityRequirement": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"availabilityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED"
}
}
],
"cvssMetricV31": [
{
"source": "[email protected]",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"timestamp": "2026-10-30T19:59:29.771309Z",
"id": "CVE-2026-78403",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
]
},
"weaknesses": [
{
"source": "[email protected]",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-121"
},
{
"lang": "en",
"value": "CWE-862"
}
]
}
],
"references": [
{
"url": "https://supportportal.thalesgroup.com/csm?id=kb_article_view&sys_kb_id=50fc9f3b3b005f10bba8b41864e45a61&sysparm_article=KB0031216",
"source": "[email protected]"
}
]
}