CVE-2026-9127

Full vulnerability record from the local CVENow database.

Description

A remote code execution security issue exists within Studio 5000 Logix Designer® due to incorrect authorization on a configuration file. This can allow any authenticated user to modify the paths of external tools configured within the application. If exploited, an attacker could alter the configuration to point to a malicious executable, resulting in arbitrary code execution when any user interacts with the external tools functionality.

Severity
HIGH
CVSS score
7.3 (v4.0)
Vulnerability status
Analyzed
Source identifier
Published
2026-07-14 16:17:05.347000
Last modified
2026-10-24 21:10:00.130000
View original CVE JSON
{
  "id": "CVE-2026-9127",
  "sourceIdentifier": "[email protected]",
  "published": "2026-07-14T16:17:05.347",
  "lastModified": "2026-10-24T21:10:00.130",
  "vulnStatus": "Analyzed",
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A remote code execution security issue exists within Studio 5000 Logix Designer® due to incorrect authorization on a configuration file. This can allow any authenticated user to modify the paths of external tools configured within the application. If exploited, an attacker could alter the configuration to point to a malicious executable, resulting in arbitrary code execution when any user interacts with the external tools functionality."
    },
    {
      "lang": "es",
      "value": "Existe un problema de seguridad de ejecución remota de código dentro de Studio 5000 Logix Designer® debido a una autorización incorrecta en un archivo de configuración. Esto puede permitir a cualquier usuario autenticado modificar las rutas de las herramientas externas configuradas dentro de la aplicación. Si se explota, un atacante podría alterar la configuración para que apunte a un ejecutable malicioso, lo que resultaría en ejecución de código arbitrario cuando cualquier usuario interactúe con la funcionalidad de herramientas externas."
    }
  ],
  "affected": [
    {
      "source": "[email protected]",
      "affectedData": [
        {
          "vendor": "Rockwell Automation",
          "product": "Studio 5000 Logix Designer",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "V35.00,34.00,34.01, 33.00,33.02, 32.00-32.04 and older",
              "status": "affected"
            }
          ]
        }
      ]
    }
  ],
  "metrics": {
    "cvssMetricV40": [
      {
        "source": "[email protected]",
        "type": "Secondary",
        "cvssData": {
          "version": "4.0",
          "vectorString": "CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "baseScore": 7.3,
          "baseSeverity": "HIGH",
          "attackVector": "LOCAL",
          "attackComplexity": "HIGH",
          "attackRequirements": "PRESENT",
          "privilegesRequired": "LOW",
          "userInteraction": "ACTIVE",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnAvailabilityImpact": "HIGH",
          "subConfidentialityImpact": "HIGH",
          "subIntegrityImpact": "HIGH",
          "subAvailabilityImpact": "HIGH",
          "exploitMaturity": "NOT_DEFINED",
          "confidentialityRequirement": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "valueDensity": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "source": "[email protected]",
        "type": "Primary",
        "cvssData": {
          "version": "3.1",
          "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:C/C:H/I:H/A:H",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "attackVector": "LOCAL",
          "attackComplexity": "HIGH",
          "privilegesRequired": "LOW",
          "userInteraction": "REQUIRED",
          "scope": "CHANGED",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "availabilityImpact": "HIGH"
        },
        "exploitabilityScore": 0.8,
        "impactScore": 6.0
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "timestamp": "2026-07-14T15:54:40.733635Z",
          "id": "CVE-2026-9127",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "role": "CISA Coordinator",
          "version": "2.0.3"
        }
      }
    ]
  },
  "weaknesses": [
    {
      "source": "[email protected]",
      "type": "Secondary",
      "description": [
        {
          "lang": "en",
          "value": "CWE-863"
        }
      ]
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "operator": "OR",
          "negate": false,
          "cpeMatch": [
            {
              "vulnerable": true,
              "criteria": "cpe:2.3:a:rockwellautomation:studio_5000_logix_designer:*:*:*:*:*:*:*:*",
              "versionEndIncluding": "32.04",
              "matchCriteriaId": "2C546B21-3BC4-419A-BFE8-DC7E4B54F5E7"
            },
            {
              "vulnerable": true,
              "criteria": "cpe:2.3:a:rockwellautomation:studio_5000_logix_designer:*:*:*:*:*:*:*:*",
              "versionStartIncluding": "33.00",
              "versionEndExcluding": "33.02",
              "matchCriteriaId": "EB0E80CD-D962-427B-A9BB-EB8512316ACF"
            },
            {
              "vulnerable": true,
              "criteria": "cpe:2.3:a:rockwellautomation:studio_5000_logix_designer:*:*:*:*:*:*:*:*",
              "versionStartIncluding": "34.00",
              "versionEndExcluding": "34.02",
              "matchCriteriaId": "9BAFE675-E30C-4B9A-BF51-EFF97162CCEB"
            },
            {
              "vulnerable": true,
              "criteria": "cpe:2.3:a:rockwellautomation:studio_5000_logix_designer:35.00:*:*:*:*:*:*:*",
              "matchCriteriaId": "25EF8390-E355-4C44-9D28-8086BC76F656"
            }
          ]
        }
      ]
    }
  ],
  "references": [
    {
      "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1783.html",
      "source": "[email protected]",
      "tags": [
        "Vendor Advisory"
      ]
    }
  ]
}